Device description
LED
Fo Alarm
(500NMD11 and
500NMD20)
DSL Alarm
(500NMD02)
L
S
During start-up all displays light up shortly for about 1 second. As soon as the start-up has
been finalized successfully (about 30 seconds after switching on the device) the LED "Ready"
switches to green.
4.9

Controls

4.9.1

Reset Button

Pressing the reset button restarts the device and loads the saved configuration (startup-
config or stick-config). As a protection against accidental triggering, the reset button is in a
concealed place and be reached with a pointed tool (e.g. paper clip).
If the running configuration (= running-config) does not match the saved configuration (=
startup-config) it is lost with the restart.
All established communication connections will be lost during restart.
4.10

Accessories

4.10.1

Optical SFP Modules

Accessories ordering information
500SMM02 SFP Module multi-mode
500SMM02 R0001
short range up to 2 km
Accessories ordering information
500SSM15 SFP Module single-mode
500SSM15 R0001
intermediate range up to 15 km
1KGT150966 V000 1
Description
SFP Alarm
DSL Alarm
Ethernet connection
Ethernet data rate
A D V I C E
A D V I C E
Function
off
No alarm
red
Alarm about the SFP inter-
face(s)
off
No alarm
red
Alarm about DSL interfaces
off
No connection
green
Link established
flash
Activity (send or receive)
off
Data rate 10 Mbps
orange
Data rate 100 Mbps