Christie DHD700 Instruction Sheet page 4

Lamp/filter replacement
Hide thumbs Also See for DHD700:

Advertisement

RESETTING THE FILTER COUNTER
1. Switch the power button to ON.
2. Press the MENU button to display the On-Screen
Menu. Use the
frame pointer to the Setting Menu icon (Figure 3).
3. Use the Point
pointer to Filter counter and then press the SELECT
button. A dialog box appears showing the Used time
option and the Scrolls remaining option. Use the Point
buttons to select Used time.
4. Used time shows the total accumulated time of the filter
use, a timer setting option, and the Reset option. Select
Reset and the "Filter counter Reset?" appears. Select
[Yes] to continue.
5. Another confirmation dialog box appears, select [Yes]
to reset the Filter counter.
NOTES: 1) The FILTER TIME value shown on the EASY
menu is the use time since the last time the FILTER TIME
was reset. Refer to the value for proper maintenance. 2) Do
not reset the FILTER TIME without replacing a filter.
RESETTING THE FILTER COUNTER
1. Switch the power button to ON.
2. Press the MENU button to display the On-Screen
Menu. Use the Point
pointer to the Setting Menu icon.
3. Use the Point
to Filter counter and then press the SELECT button. A
dialog box appears showing the Used time option and
the Scrolls remaining option. Use the Point
to select Scroll(s) remaining.
4.
Scroll(s) remaining shows the number of the remaining
scrolls and the Reset option. Select Reset and the "Scroll
counter Reset?" appears. Select [Yes] to continue.
5. Another confirmation dialog box appears, select [Yes]
to
reset the Scroll counter.
4 of 4
cursor buttons to move the red
buttons to move the red frame
buttons to move the red frame
buttons to move the red frame pointer
Figure 4 Filter Counter
buttons
Figure 5 Scroll Counter
DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet
020-000207-02 Rev. 1 (10-2010)