Download Print this page

Christie DHD700 Instruction Sheet

Lamp/filter replacement
Hide thumbs Also See for DHD700:

Advertisement

Quick Links

DHD700/800 Lamp/Filter Replacement
INTRODUCTION
These instructions outline the details for Lamp and Filter replacement in the DHD700 (Model No. 103-
022105-01) and DHD800 (Model No. 103-029102-01) projectors. NOTICE: Use only a Christie
approved Lamp and Filter Kit for your specific projector model.
KITS REQUIRED
DHD700
003-120504-01 (Replacement Lamp)
003-001726-01 (Replacement Air Filter)
DHD800
003-120577-01 (Replacement Lamp)
003-003378-01 (Replacement Air Filter)
INSTRUCTIONS
LAMP REPLACEMENT
When the projection lamp reaches its end of life, the Lamp
Replacement icon appears on the screen and the LAMP 1/2
REPLACE indicator lights orange. Replace the lamp with a
new one promptly. The timing when the LAMP 1/2
REPLACE indicators should light depends on the lamp mode.
NOTES: 1) The Lamp replacement icon will not appear when
the Display function is set to "Off", or during "Freeze". 2) It
is recommended that both lamps be changed at the same time
in order to maintain picture quality (better color balance and
brightness).
DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet
020-000207-02 Rev. 1 (10-2010)
Instruction Sheet
Figure 1 Lamp Replacement Icon
1 of 4

Advertisement

loading

Summary of Contents for Christie DHD700

  • Page 1 Instruction Sheet INTRODUCTION These instructions outline the details for Lamp and Filter replacement in the DHD700 (Model No. 103- 022105-01) and DHD800 (Model No. 103-029102-01) projectors. NOTICE: Use only a Christie approved Lamp and Filter Kit for your specific projector model.
  • Page 2 4. Set the new lamp unit into place and tighten the 2 screws that attach it to the projector. 5. Slide the lamp cover back into place, and tighten the lamp cover screw. Figure 2 Lamp Replacement 2 of 4 DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet 020-000207-02 Rev. 1 (10-2010)
  • Page 3: Replacing The Filter Cartridge

    Such conditions may degrade the quality of the projected image. When the symptoms above are noticed, contact your authorized dealer or service station for proper cleaning. Figure 3 Filter Replacement DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet 3 of 4 020-000207-02 Rev. 1 (10-2010)
  • Page 4 Reset option. Select Reset and the “Scroll counter Reset?” appears. Select [Yes] to continue. 5. Another confirmation dialog box appears, select [Yes] reset the Scroll counter. Figure 5 Scroll Counter 4 of 4 DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet 020-000207-02 Rev. 1 (10-2010)