Sony MVS-8000X-C Installation Manual page 32

Switcher processor pack, multi format switcher processor.
Hide thumbs Also See for MVS-8000X-C:
Table of Contents

Advertisement

D3605 (B-1) : POWER
Power supply status indication.
Lights in green when all power supply on the board are
normally. If the power supply has abnormality, turns off.
D3606 (B-1) : BECON
For future expansion.
D3607 (B-1) ; STATUS
For future expansion.
D3701 (L-1) : CF LED0
CF card controller status indication.
Lights or blinks when communicate with CF card.
D3702 (M-1) : CF LED2
CF card controller status indication. (Not used)
D3703 (M-1) : CF LED1
CF card controller status indication. (Not used)
D3704 (M-1) : CF DET
Lights when CF card is inserted.
D4101 to D4103 (D-2) : DB0 ETHER
Ethernet communication status indication for maintenance.
. D4101 (100)
: Lights when linked by 100base-
TX.
. D4102 (1000)
: Lights when linked by
1000base-T.
. D4103 (LINK/ACT) : Lights when linked, and blinks
when communicating.
< Switch >
S401 (F-1) : CA RESET
Reset the board.
S402 (F-1) : SWER RESET
Reset the all system, and restart.
S501 (M-1) : MON
Start up in monitor mode when press S401, S402 or power
on while pressing this switch.
S901/S904 (E-1, F-1) : SETTING1, SETTING2
Sets the software mode.
Default setting when shipped from the factory is all OFF.
1-26
S902 (G-1) : GROUP ID
Sets the GROUP ID for connecting LAN. Do not change
the setting.
In the default settings when shipped from the factory, bit 1
is set to ON and others are set to OFF.
S903 (G-1) : UNIT ID
Sets the UNIT ID for connecting LAN. Do not change the
setting.
In the default settings when shipped from the factory, bit 1
is set to ON and others are set to OFF.
< LED on the CPU-DP Module >
D1 (L-6) : 3.3 V
Power supply status indication.
Lights when +3.3 V power is supplied to the regulator on
CPU-DP module.
D2 (L-6) : 2.5 V
Power supply status indication.
Lights when +2.5 V power is supplied normally.
D3 (L-6) : 1.8 V_DDR
Power supply status indication.
Lights when +1.8 V power is supplied normally to the
DDR2 on CPU-DP module.
D4 (L-6) : 1.2 V
Power supply status indication.
Lights when +1.2 V power is supplied normally.
D5 (L-6) : 1.1 V
Power supply status indication.
Lights when +1.1 V power is supplied normally.
D6 (R-4) : CD
Lights when the connector on CPU-DP module connected
to the base board normally.
D7 (N-2) : RUN
Lights when complete the boot process normally of CPU-
DP module.
D8 to D11 (N-2) : STATUS LED1 to 4
Internal status indication of CPU-DP module.
Controlled by software.