Table Of Contents; Indication To The Manual; Description Of The Product - Brinkmann SAL1130 Series Operating Instructions Manual

Immersion pumps
Table of Contents

Advertisement

Brinkmann Immersions Pumps of the Series STA/SAL1130 ... 2000,
Contents
1
Indication to the manual .................................... 2
2
Description of the Product .............................. 2-3
3
Safety instructions ............................................. 4
4
Transportation and Storage ............................... 4
5
Installation and Connection ............................ 5-6
6
Start-up / Shut-down ......................................... 6
7
Operation ........................................................... 6

1 Indication to the manual

This operating manual gives basic instructions which
are to be observed during installation, operation and
maintenance of the pump. It is therefore imperative
that this manual be read by the responsible personnel
and operator prior to assembly and commissioning. It
is always to be kept available at the installation site.
1.1
Identification of safety instructions in the
operating manual
Safety instructions given in this manual non-
compliance with which would affect safety are identi-
fied by the following symbol
Safety sign according with ISO 3864 - B.3.1
or where electrical safety is involved, with:
Safety sign according with ISO 3864 - B.3.6
Where non-compliance with the safety instructions
may cause a risk to the machine and it's function the
word
ATTENTION
is inserted.

2 Description of the Product

2.1
General description of the pump
Pumps of this type are one-stage rotary pumps where
the impellers are fixed on the driving shaft extension.
The pump shaft and motor shaft are interconnected
by means of a shaft clamp. Pump and motor form a
compact and space-saving unit. These pumps are
fitted out with semi-open impellers and a suction
screw SAL, SGL, SFL.
Vertically mounted pumps are equipped with a mount-
ing flange. The pump end immerses into the tank and
the motor extends vertically above the tank.
BAS6530
SGL1400 and SFL1360...1860
8 Servicing and Maintenance ............................... 6
9 Troubleshooting Guide ...................................... 7
10 Spare Parts ..................................................... 8-9
11 Repair ................................................................ 9
12 Disposal ............................................................. 9
13 Terms and Conditions ................................ 10-11
2.2
The immersion pumps of the series STA/SAL, SGL
and SFL are suitable for handling contaminated
coolants within the limiting application in accordance
with table 1.
The pumps of SAL, SGL and SFL are suitable for
handling extremely inflated fluids (grinding oils SGL).
Limit of Application (Table 1)
The pumps are to be operated within their design
limits. Applications outside of these limits are not
approved. The manufacturer is not responsible for any
damages resulting from use of the pumps in such
applications.
04/2019
Edition
Intended use
Type
STA/SAL, SGL, SFL
Mediums
Coolant, cooling- and cutting-oils
grinding oils SGL
Chip material
Aluminium, steel, coloured steels
SFL
max. chip to coolant ratio by weight:
1.0%
...200 SSU (...45 mm
Kinetic viscosity
of the medium
30 ... 175 °F (0 ... 80 °C)
Temperature of
medium
Particle-size in
0.67 Inches (17 mm)
the medium
STA/SAL1130, 1600
0.75 Inches (19 mm)
0.55 Inches (14 mm)
0.47 Inches (12 mm) SGL1
0.55 Inches (14 mm)
SFL1360...1860
min. delivery
1% of Q max.
volume
Dry running
Dry running causes increased wear
and should be avoided.
During the test of the direction of
rotation (< 30 s) permissible.
Motor cycle
Motors from 6.7 HP to 12 HP max.
time per hour
20
for
from 13.4 HP to 29.5 HP max. 15
STA/SAL,SGL
SFL
The pump SFL should be operated
in continual operation mode, not
pulsed mode.
Ambient tempe-
104 °F (40 °C)
rature
Set-up altitude
3280 ft (1000 m)
ATTENTION
2
/s)
STA/SAL2000
SGL1400
700
Page 2 of 11

Hide quick links:

Advertisement

Table of Contents
loading