Atlas Copco GA 160 VSD Instruction Book page 82

Hide thumbs Also See for GA 160 VSD:
Table of Contents

Advertisement

Elektronikon MkIV
Step
1
2
3
4
Example of the main menu
"Status data"
"Measured Data"
"Counters"
"Mainscreen"
F1
Example of the main display
Example of Main screen of GA 110 VSD up to GA 160 VSD compressors
"Compressor Outlet"
.
"Compressor Speed"
"Menu"
F1
80
Action
Regularly check the display for readings and messages. Normally, the main display is
shown, indicating the compressor outlet pressure, the status of the compressor and the
functions of the keys below the display.
Always check the display and remedy the problem if alarm LED (7) is lit or flashing.
The display will show a service message if a service plan interval has been exceeded or
if a service level for a monitored component has been exceeded. Carry out the service
actions of the indicated service plans or replace the component and reset the relevant
timer.
Regularly check the actual compressor status by pressing the arrow down key from the
main screen.
F2
F2
F3
7.5 bar
2100 rpm
F3
Instruction book