Atlas Copco GA 160 VSD Instruction Book page 44

Hide thumbs Also See for GA 160 VSD:
Table of Contents

Advertisement

Function
To modify a number of parameters. Consult the menu flow in section Control programs.
Procedure
Starting from the Main screen (see
• Press the key "Menu" (F1).
• Press the arrow down key (1) until "Modify Parameters" is followed by an arrow pointing to the right.
• Activate the menu by pressing tabulator key (2).
• Press the arrow down key (1) to scroll until "Configuration" is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2): the first item will appear. Scroll through the display until
the option to be modified is followed by a horizontal arrow. Select the option by pressing the tabulator
key (2).
• In case of the option "Time", the second line on the screen indicates the actual setting, e.g. "14:30". To
modify this setting, press the key "Modify" (F2); the first field "14" will blink.
• Use the scroll keys (1) to change the setting, then press the tabulator key (2) to go to the next field "30".
The setting of this field can now be modified using the scroll keys (1).
• Press the key "Program" (F1) to program the new value or the key "Cancel" (F3) to cancel the modification
operation (the original value will be retained).
• The procedure to modify other parameters is similar.
Programming compressor control modes
The compressor can be controlled locally, remotely or via a local area network (LAN).
Procedure
• Activate the menu "Configuration" as described above.
• Scroll through the display until the option "C.C.M." is indicated and press the "Modify" key. Following
screen appears:
.
"C.C.M."
.
"Program"
F1
• "Local Control" is blinking, use the scroll keys (1) to select the desired control mode.
• Press the key "Program" to program the new control mode or "Cancel" to quit without reprogramming.
42
Main screen
menu):
F2
"Local Control"
"Cancel"
F3
Instruction book
APF192090