Carrier AquaEdge 19XR Series Start-Up, Operation And Maintenance Instructions Manual page 79

Single stage and two-stage semi-hermetic centrifugal liquid chillers with pic 6 controls and r-134a/r-513a 50/60 hz
Table of Contents

Advertisement

WATERBOX DESCRIPTION
NIH, 1 Pass Cover, 150 psig (1034 kPa)
NIH, 2 Pass Cover, 150 psig (1034 kPa)
NIH, 3 Pass Cover, 150 psig (1034 kPa)
MWB End Cover, 150 psig (1034 kPa)
NIH/MWB Return Cover, 150 psig (1034 kPa)
NIH, 1 Pass Cover, 300 psig (2068 kPa)
NIH, 2 Pass Cover, 300 psig (2068 kPa)
NIH, 3 Pass Cover, 300 psig (2068 kPa)
NIH Plain End Cover, 300 psig (2068 kPa)
MWB End Cover, 300 psig (2068 kPa)
MWB Return Cover, 300 psig (2068 kPa)
LEGEND
NIH
— Nozzle-in-Head
MWB — Marine Waterbox
STD — Standard
Table 29 — 19XR Waterbox Cover Weights Condenser Frames 2, 3
WATERBOX DESCRIPTION
NIH, 1 Pass Cover, 150 psig (1034 kPa)
NIH, 2 Pass Cover, 150 psig (1034 kPa)
NIH, 3 Pass Cover, 150 psig (1034 kPa)
MWB End Cover, 150 psig (1034 kPa)
NIH/MWB Return Cover, 150 psig (1034 kPa)
NIH, 1 Pass Cover, 300 psig (2068 kPa)
NIH, 2 Pass Cover, 300 psig (2068 kPa)
NIH, 3 Pass Cover, 300 psig (2068 kPa)
NIH Plain End Cover, 300 psig (2068 kPa)
MWB End Cover, 300 psig (2068 kPa)
MWB Return Cover, 300 psig (2068 kPa)
LEGEND
NIH
— Nozzle-in-Head
MWB — Marine Waterbox
STD — Standard
Table 28 — 19XR Waterbox Cover Weights Cooler Frames 2, 3
FRAME 2
STD
NOZZLES FLANGED
287
287
294
315
243
411
411
433
291
619
445
FRAME 2
STD
NOZZLES
260
265
272
234
225
379
379
401
270
474
359
ENGLISH (LB)
COOLER
FRAME 3
STD
NOZZLES FLANGED
318
287
318
340
287
340
310
294
310
315
315
315
243
243
243
486
411
486
518
411
518
468
433
468
291
291
291
619
619
619
445
445
445
NOTE: Weight for NIH 2-pass cover, 150 psig (1034 kPa), is included in
the heat exchanger weights shown in the heat exchanger weight tables.
ENGLISH (LB)
CONDENSER
FRAME 3
STD
FLANGED
FLANGED
NOZZLES
297
260
297
318
265
318
288
272
288
234
234
234
225
225
225
454
379
454
486
379
486
436
401
436
270
270
270
474
474
474
359
359
359
NOTE: Weight for NIH 2-pass cover, 150 psig (1034 kPa), is included in
the heat exchanger weights shown in the heat exchanger weight tables.
79
METRIC (KG)
COOLER
FRAME 2
STD
STD
NOZZLES FLANGED
NOZZLES FLANGED
130
144
130
130
154
130
133
141
133
143
143
143
110
110
110
186
220
186
186
235
186
196
212
196
132
132
132
281
281
281
202
202
202
METRIC (KG)
CONDENSER
FRAME 2
STD
STD
FLANGED
NOZZLES
NOZZLES
118
135
118
120
144
120
123
131
123
106
106
106
102
102
102
172
206
172
172
220
172
182
198
182
122
122
122
215
215
215
163
163
163
FRAME 3
144
154
141
143
110
220
235
212
132
281
202
FRAME 3
FLANGED
135
144
131
106
102
206
220
198
122
215
163