Carrier AquaEdge 19XR Series Start-Up, Operation And Maintenance Instructions Manual page 5

Single stage and two-stage semi-hermetic centrifugal liquid chillers with pic 6 controls and r-134a/r-513a 50/60 hz
Table of Contents

Advertisement

Description
19XR — High Efficiency Semi-Hermetic
Centrifugal Liquid Chiller
19XRV — High Efficiency Semi-Hermetic
Centrifugal Liquid Chiller with
Unit-Mounted VFD
Evaporator Size†
10-12 (Frame 1)
15-17 (Frame 1)
20-22 (Frame 2)
30-32 (Frame 3)
35-37 (Frame 3)
40-42 (Frame 4)
45-47 (Frame 4)
50-54 (Frame 5)
5A-5C (Frame 5)**
55-59 (Frame 5)
5F-5H (Frame 5)**
5K-5R (Frame 5)††
5T-5Z (Frame 5)††
60-64 (Frame 6)
6K-6R (Frame 6)††
65-69 (Frame 6)
6T-6Z (Frame 6)††
70-74 (Frame 7)
7K-7R (Frame 7)††
75-79 (Frame 7)
7T-7Z (Frame 7)††
80-84 (Frame 8)
8K-8R (Frame 8)††
85-89 (Frame 8)
8T-8Z (Frame 8)††
Condenser Size†
10-12 (Frame 1)
15-17 (Frame 1)
20-22 (Frame 2)
30-32 (Frame 3)
35-37 (Frame 3)
40-42 (Frame 4)
45-47 (Frame 4)
50-54 (Frame 5)
55-59 (Frame 5)
60-64 (Frame 6)
65-69 (Frame 6)
70-74 (Frame 7)
75-79 (Frame 7)
80-84 (Frame 8)
85-89 (Frame 8)
*
Digit 15 will refer to the Gear Code for the following
models:
1. Digit 10 (Compressor Frame) is C or E.
2. Digit 10 (Compressor Frame) is 3 and Digit 13 of
the Motor Code is U.
† Frame sizes 1 through 6 available on single-stage
units only.
** Refer to 19XR,XRV Computer Selection Program for
details on these sizes.
†† Frame sizes with K-R and T-Z are with 1-in. OD evap-
orator tubing.
*** Refer to the 19XR,XRV Computer Selection Program
for motor size details.
Fig. 1 — 19XR,XRV Single-stage Compressor and Two-stage Compressor Frame Size C and E
52
51 3
19XR
8
5
H
UG
T* 64
Special Order Indicator
– — Standard
S — Special Order
Motor Voltage Code
Code Volts-Phase-Hertz
60 — 200-3-60
61 — 230-3-60
62 — 380-3-60
63 — 416-3-60
64 — 460-3-60
65 — 575-3-60
66 — 2400-3-60
67 — 3300-3-60
68 — 4160-3-60
69 — 6900-3-60
50 — 230-3-50
52 — 400-3-50
53 — 3000-3-50
54 — 3300-3-50
55 — 6300-3-50
5A
5B
6A
6B
6C
Motor Efficiency Code
Compressor Frame 2, 3, 4, 5
H — High Efficiency
S — Standard Efficiency
Gear Code
Compressor Frame C
C,E,G,J,M,P — Gear Ratio
Compressor Frame E
A,B,C,D,E— A-E Gear Ratio
Compressor Frame 3, U Motor
R,S,T,U,V,W— R-W Gear Ratio
Motor Code***
Impeller Diameter
Impeller Shroud
Compressor Frame
2, 3, 4, 5 — Single-Stage
C, E — Two-Stage
10000-3-50
11000-3-50
11000-3-60
11000-3-60
13800-3-60

Hide quick links: