OHAUS Valor 2000 V22PW Faq
OHAUS Valor 2000 V22PW Faq

OHAUS Valor 2000 V22PW Faq

Advertisement

Topic:

How to switch between units of measure

With this model, you can only select one unit of measure at a time, which you need to activate from the
Service menu (see next section:
You can also click

How to select/display the active unit of measure

Enabling or disabling the units of measure can be accomplished in the SERVICE > S.UNIT sub-menu
(you can also download the user manual
You can also click
To enable another unit of measure, you need to disable the current active unit first (the unit displayed
when the scale is turned on).
For the following example, the current active unit is grams (g), and you want to change to pounds (lb):
1. With the scale off, press and hold [On/Zero] and [Tare]
together for up to 15 seconds – the scale will cycle through
power up and weigh mode before RAMP is displayed.
2. Release the keys after RAMP is displayed.
3. When RAMP is displayed – press [Tare] (no) repeatedly
through each succeeding sub-menus
DIV5 > L.IR FL) until S.UNIT is displayed.
* DO NOT press [On/Zero]
Notes:
a) If you overshoot the S.UNIT sub-menu, just keep pressing [Tare] until S.UNIT is displayed again.
b) To abort at any time, long press [On/Zero] to turn the scale off. Repeat from Step 1.
For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST
This list compiles frequently asked questions about the Valor 2000 V22PW
(plastic housing only) model:
a) How do I switch between units of measure
b) How do I select and display the active unit of measure
c) How do I calibrate my unit
d) How do I clear an Err 9 Data error?
How to select and display the active unit of
here
to view a short video on this topic.
here
here
to view a short video on this topic.
*
(LIN > SPAN > CAP >
as these sub-menus are displayed.
Valor 2000 V22PW FAQ
– refer to Section 3.5: Unit Menu).
measure).
AppNotes.v20180720_ AG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Valor 2000 V22PW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OHAUS Valor 2000 V22PW

  • Page 1 To abort at any time, long press [On/Zero] to turn the scale off. Repeat from Step 1. AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...
  • Page 2 10. UNIT LB is displayed – press [On/Zero] to select. 11. OFF LB is displayed – press [Tare] to switch to ON LB. AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...
  • Page 3 The activated unit of measure (lb in this example) is now displayed. AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...
  • Page 4 The calibration process can be aborted any time by turning the scale off. AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...
  • Page 5 The display will flash –C-- until the zero reading is stored, then shows the requested calibration value (30lb in this example) AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...
  • Page 6 10. The scale returns to weighing mode and the error is cleared. If this still does not resolve this issue, please contact Ohaus Technical Support. AppNotes.v20180720_ AG For any further questions, please e-mail us at techsupport@ohaus.com, or call us at 973-377-9000 #2 or ext. 7852 from 8AM to 5PM EST...

Table of Contents