Siemens SIMATIC NET CP 5613 A2 Operating Instructions Manual page 27

Pg/pc - profibus
Hide thumbs Also See for SIMATIC NET CP 5613 A2:
Table of Contents

Advertisement

Technical specifications
Interfaces
Mode of the PROFIBUS interface
PROFIBUS controller used
Data transfer
Transmission speed
Electromagnetic compatibility (EMC)
Emission
Noise immunity on signal lines
Immunity to discharges of static electricity
Immunity to RF interference
Climatic Conditions
Temperature
Operation
Transportation/storage temperature
Relative humidity
26
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Floating (interface signals),
non-floating (cable shield)
CP 5613 A2 / CP 5614 A2
Master: ASPC2R ST E2a
CP 5614 A2
Slave: DPC31
9.6 kbps to 12 Mbps
Class B to EN 55022
FCC class B
+/- 2 kV
to EN 61000-4-5, surge
+/- 6 kV, contact discharge to
IEC 61000-4-2
10 V/m at
80 MHz to 2 GHz to EN 61000-4-3
10 V/m 50 % ON period at 900 MHz and 1.89 GHz
to EN 61000-4-3
10 V/m with 80 % amplitude modulation
with 1 kHz,
9 kHz - 80 MHz to EN 61000-4-6
Tested to:
DIN EN 60068-2-1,
DIN EN 60068-2-2,
DIN EN 60068-2-14
Temperature change max. 10 K/h
-40 °C through +70 °C
Temperature change max. 20 K/h
tested to DIN IEC 60068-2-78
in operation
85% at 30℃ (no condensation)
tested to DIN IEC 60068-2-30:
storage/transportation:
5% at 25 - 55 °C (no condensation)
Operating Instructions, 12/2012, C79000-G8976-C301-02