1. General description

The SPO pump is available in two versions:
• pump with suction strainer for submerged installa-
tion and
• pump with base plate for dry installation.
The pump is available with or without float switch.

2. Applications

SPO pumps can be used in
• wells
• first collection tanks or reservoirs
• Roman wells
• streams
• domestic systems for distributing water and water-
ing.
The pump must not be used in or at swim-
ming pools, garden ponds, etc. when there
are persons in the water.
6

2.1 Pumped liquids

The SPO pumps are designed for pumping thin,
Page
clean, non-aggressive and non-explosive liquids, not
6
containing solid particles or fibres.
6
6

3. Transportation and storage

6
6

3.1 Transportation

6
The pump should not be exposed to unnecessary im-
6
pact and shocks.
6
Note: Do not lower or lift the pump by means of the
7
supply cable.
7
8

3.2 Storage

8
8
The pump must be stored indoors in a dry position.
9
Note: Pumps with base plate must be drained before
9
storage.
9
9

4. Technical data

9
See pump nameplate.
9
9
Liquid temperature:
9
0°C to +40°C.
10
Installation depth:
11
Maximum 20 metres below liquid level (pump with
11
suction strainer).
Storage temperature:
-10°C to +40°C.
Operating pressure:
Maximum 10 bar (pump with base plate).
Enclosure class:
IP 68.
Sound pressure level:
The sound pressure level of the pump is lower than
the limiting values stated in the EC Council Directive
98/37/EC relating to machinery.

5. Installation

Before starting work on the pump/motor,
make sure that the electricity supply has
been switched off and that it cannot be ac-
cidentally switched on.
The pump must be installed in a frost-free location.
Note: The pump must not be installed hanging from
the supply cable.
The pump is not allowed to run against a closed dis-
charge valve.
Install the pipes so that the pump is not exposed to
mechanical stress.
Pump with base plate:
Install the pipes so that air locks are avoided, espe-
cially on the suction side of the pump, see fig. 1.
It is recommended to fit a non-return valve in the
suction pipe.