Installation
Note the order in which the
gasket (1) and metering
diaphragm (2) are installed.
: Align the gasket (1) and metering
diaphragm (2) so that the pins
(arrows) engage in the holes
2
: Align the end cover (1) so that the
connector (arrow) points towards
the choke shutter
: Align the end cover (1) until the
holes engage in the pins (2)
70
1
1
2
1
: Fit and tighten screws (1)
– Check that the metering
diaphragm and gasket are
correctly seated, then tighten the
screws crosswise
– Push sleeve onto the connector
– Reassemble remaining parts in
reverse order

10.4.2 Inlet needle

1
– Remove the metering
2
diaphragm,
b 10.4.1
1
: Unscrew the screw (1)
2 1
1
1
: Pull the inlet control lever (1) with
spindle (2) out of the groove in
the inlet needle
The spring under the inlet control
lever may pop out.
2 1
: Pull out the inlet needle (2)
: Take out and examine the
spring (1), replace if necessary
: The sealing cone of the inlet
needle must be replaced if a
circular indentation (arrow) is
visible on its tip.