Between Indoor unit and Outdoor unit Connection Cable Specifications(Common in use)
Power supply
1Φ, 220-240V, 50Hz
f Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible
f
cord . (Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
1-phase terminal block spec
AC power : M5 screw
1(L) 2(N)
L
15
12
3-phase terminal block spec
AC power : M4 screw
1(L) 2(N)
L1(R)
L2(S)
9 . 9 5
14
Power supply
Max/Min(V)
±10%
When installing the indoor unit in a computer room or net work room, use the
double shielded (Tape aluminum / polyester braid + copper ) cable of FROHH2R
type .
Communication : M4 screw
N
Communication : M4 screw
L3(T)
N
11 . 5 5
Indoor Power Cable
2 . 5 mm² , 3wires
Communication : M3 screw
10 . 1
11 . 4
10 . 1
11 . 4
Communation Cable
0 . 7 5~1 . 5 mm², 2wires
6 . 7
9 . 7
Communication : M3 screw
6 . 7
9 . 7