Air Conditioner
installation manual
imagine
the possibilities
Thank you for purchasing this Samsung product.
ACTTTFCADEHT/ACTTTFCADGHT
ACTTTFCAPEHT/ACTTTFCAPGHT
ACTTTFCAFEHT/ACTTTFCASEHT
RCTTTDHXET/RCTTTDHXGT
RCTTTPHXEA/RCTTTPHXGA
RCTTTZHXEA/RCTTTSHXEA
ACTTTHCAPKH/ACTTTHCAPNH
ACTTTHCADKH/ACTTTHCADNH
ACTTTJXADTH/ACTTTJXADEH1

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AC090FCAPEH

  • Page 1 ACTTTFCADEHT/ACTTTFCADGHT ACTTTFCAPEHT/ACTTTFCAPGHT ACTTTFCAFEHT/ACTTTFCASEHT RCTTTDHXET/RCTTTDHXGT RCTTTPHXEA/RCTTTPHXGA RCTTTZHXEA/RCTTTSHXEA ACTTTHCAPKH/ACTTTHCAPNH ACTTTHCADKH/ACTTTHCADNH ACTTTJXADTH/ACTTTJXADEH1 Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. DE EL DB98-32793A-25...
  • Page 2: Table Of Contents

    Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Preparation for outdoor unit installation .
  • Page 3: Safety Precautions

    . f This manual explains how to install an indoor unit with a split system with two SAMSUNG units . The use of other types of units with different control systems may damage the units and invalidate the warranty . The manufacturer shall not be responsible for damages arising from the use of non compliant units .
  • Page 4 Safety precautions Installing the unit f IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines . Always disassemble the electric lines before the refrigerant tubes . f Upon receipt, inspect the product to verify that it has not been damaged during transport . If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer .
  • Page 5: Preparation For Outdoor Unit Installation

    Preparation for outdoor unit installation The air conditioner uses R-410A refrigerant . AC090FCATEH/AC100FCADTH/AC100FCASEH/RC090THXEA/RC100DHXTA/RC100SHXEA/AC071HCAPKH/ A Type AC090HCADTH/AC100HCADTH/AC120HCADTH/AC100JXADTH/AC120JXADTH/AC100JXADEH1 Heat pump (Unit : mm) AC100FCAPTH/RC100DHXEH/RC100PHXTA/RC100DHXEG/RC125THXTT/RC125DHXEG/RC140DHXEB/RC140DHXGA/ B Type AC090HCAPKH/AC140HCADTH/AC140JXADTH Heat pump AC100FCAFTH/RC100ZHXEA/RC140PHXTA/RC140DHXEH/RC140DHXEG/RC155DHXEH/RC155DHXEG/RC180DHXGH/ C Type RC180DHXGG/AC100HCAPTH/AC120HCAPTH/AC140HCAPTH Heat pump...
  • Page 6: Deciding On Where To Install The Outdoor Unit

    Air Guide Duct (This product is not Stereo provided by Samsung) 200mm f If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position . f Make sure that the water dripping from the drain hose runs away correctly and safely .
  • Page 7 f When you install the outdoor unit at wayside, you should install it above 2m height or make sure that the heat from the outdoor unit shouldn't be in direct contact with passersby . (The ground for application :The revision of regulation for facility in building by the law of the Ministry of Construction and Transportation .
  • Page 8 Deciding on where to install the outdoor unit Space Requirements for Outdoor Unit When installing 1 outdoor unit (Unit : mm) ❋ ❋ When the air outlet is opposite the wall ❋ ❋ When the air outlet is towards the wall 2000 or more 300 or more 600 or more...
  • Page 9 When installing more than 1 outdoor unit (Unit : mm) ❋ ❋ When the air outlet is towards the wall 300 or more 600 or more 600 or more 600 or more ❋ ❋ When 3 sides of the outdoor unit are blocked by the wall 300 or more 300 or more 600 or more...
  • Page 10: Outdoor Unit Installation

    Outdoor unit installation The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall or ground) . Fix the outdoor unit with anchor bolts.
  • Page 11: Connecting The Cable

    Connecting the cable Two electronic cables must be connected to the outdoor unit . f The connection cord between indoor unit and outdoor unit . f The power cable between outdoor unit and auxiliary circuit breaker . f Specially for Russian and European market, before installation, the supply authority should be consulted to determine the supply system impendance to ensure compliance .
  • Page 12 Min. Max. Cooling Heating AC090FCADEH AC090FB4DEH 220-240 0 . 7 24 . 7 24 . 7 30 . 0 AC090FCAPEH AC090FB4PEH 220-240 1 . 0 25 . 0 25 . 0 30 . 0 AC090FCASEH AC090FBMSEH 220-240 1 . 5 23 .
  • Page 13 3 Phase Type of Model Outdoor Units Input Current [A] Power Supply Rated Voltage Range Outdoor (Down_Amp) outdoor Outdoor Unit Indoor Unit Indoor Total Volts Min. Max. Cooling Heating unit AC100FCADGH AC100FB4DEH 380-415 456 . 5 0 . 7 12 . 7 12 .
  • Page 14 Connecting the cable Between Indoor unit and Outdoor unit Connection Cable Specifications(Common in use) Power supply Communation Cable Power supply Max/Min(V) Indoor Power Cable 1Φ, 220-240V, 50Hz ±10% 2 . 5 mm² , 3wires 0 . 7 5~1 . 5 mm², 2wires f Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord .
  • Page 15 Wiring Diagram of Power Cable When using ELB for 1 phase and 3 phase 1 phase 1(L) 2(N) Cable tie Electrical Power Supply Indoor Power component box MCCB Cable clamp Main power cable Communication cable MCCB 3 phase 1(L) 2(N) L1(R) L2(S) L3(T)
  • Page 16 Connecting the cable DRED wiring diagram Outdoor unit ASSY Control out DRED SUB PBA COMMON DRED Controller DRM3 DRM2 DRM1 Cable specification Model Power cable Interconnection cable 2, 0 . 7 5mm H05RN-F (60245 IEC57) RC100/125/140/155DHXEG, RC180DHXGG DRED Connected Wire (Only for reference) Silence mode controller wiring diagram (ACTTTHCATTH/ACTTTJXADTH/AC100JXADEH1) Outdoor unit...
  • Page 17 Wiring Diagram of Connection Cord 1 phase 3 phase Indoor Unit Indoor Unit 1(L) 1(L) 2(N) 2(N) 1(L) 2(N) L1(R) L2(S) L3(T) 1(L) 2(N) Indoor Power Cable tie Cable tie Cable clamp Communication Main power cable Indoor Power Communication cable cable 3 Phase 4 Wires power cable Cable clamp...
  • Page 18 Connecting the cable Nominal Nominal dimensions dimensions Standard Standard Standard Min. Min. Max. Standard Min. Allowance Allowance Allowance Allowance for cable for screw dimension dimension dimension dimension [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] (inch [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] (inch)] (inch)] (inch)] [mm(inch)] (inch)] 8(3/16) 16(10/16)
  • Page 19 How to connect your extended power cables 1 . Prepare the following tools . Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ6 . 5 (HxOD) Width 19mm 70xØ8 . 0 (LxOD) Shape 2 . As shown in the figure, peel off the shields from the rubber and wire of the Power cable power cable .
  • Page 20 Connecting the cable 5 . Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape . A total of three or more layers of insulation is required . f Method 1 f Method 2 Insulation tape Insulation tape...
  • Page 21: Connecting The Refrigerant Pipe

    Connecting the refrigerant pipe Refrigerant piping system Maximum allowable length Items Single installation DPM installation AC100FCAPTH AC100FCAFTH RC100PHXTA AC090FCATEH RC100ZHXEA AC100FCADTH RC100DHXEH AC100FCASEH AC100FCAPTH RC100DHXEG RC090THXEA RC100PHXTA RC125THXTT RC100DHXTA RC125DHXEB RC140THXTT AC100FCADTH RC100SHXEA RC125DHXGA RC155DHXEH RC100DHXTA Applicable outdoor unit models AC071HCAPKH RC125PHXTA RC155DHXEG...
  • Page 22: Adding Refrigerant (R-410A)

    Connecting the refrigerant pipe f Temper grade and minimum thickness of the refrigerant pipe Outer diameter [mm] Minimum thickness [mm] Temper grade ø6 . 3 5 0 . 7 ø9 . 5 2 0 . 7 C1220T-O ø12 . 7 0 0 .
  • Page 23 3 . If you cannot charge the refrigerant according to the upper steps, following these : 1) Open both liquid stop valve and gas stop valve . 2) Operate the air conditioner by pressing the K2 key on the outdoor unit PCB . 3) About 30 minutes later, charge the refrigerant through the service port of gas stop valve.
  • Page 24 . This operation can only be performed by a qualified refrigeration specialist . Single installation outdoor unit Interconnection pipe length (m) Model 0~30 30~40 40~50 50~60 60~70 70~75 AC090FCADEH/AC090FCAPEH/AC100FCADTH/ RC090DHXEA/RC090PHXEA/RC100DHXTA/AC090HCADTH/ +50g/m over 30m AC100HCADTH/AC120HCADTH/AC100JXADTH/ AC120JXADTH/AC100JXADEH1 AC071HCAPTH +20g/m over 30m AC100FCAPTH/AC100FCAFEH/RC100DHXEG/RC100DHXEH/ RC100PHXTA/RC100ZHXEA/RC125THXTT/RC140THXTT/ RC155DHXEG/RC155DHXEH/RC180DHXGG/RC180DHXGH/...
  • Page 25: Installing Dpm

    Installing DPM DPM allowable Outdoor and indoor unit models DPM allowable Outdoor and indoor unit models 2 indoor units connection 3 indoor units connection 4 indoors unit connection Outdoor unit models Indoor unit Indoor unit Indoor unit AC100FCADTH AC052FBNDEH/AC052FB4DEH AC035FBNDEH AC052FBNDEH/AC052FB4DEH AC035FBNDEH AC100FCAPTH...
  • Page 26: Connecting Up And Removing Air In The Circuit

    Installing DPM In case of 4indoor units connection F1/F2 F1/F2 F1/F2 F1/F2 F1/F2 F1/F2 F1/F2 Outdoor Indoor unit #1 Indoor unit #2 Indoor unit #3 Indoor unit #4 unit Remote control ❋ ❋ The wired remote controller can be used with any of the DPM indoor units . Operation and specification f The two, the three, or the four sets of the indoor units with DPM installation which are controlled by wired and wireless remote controller work equally .
  • Page 27 2 . Referring to the illustration opposite, tighten the flare nut on section B first manually and then with a torque wrench, applying the following torque . Outdoor unit A (Gas) Outer Diameter (D) Torque (N•m) ø6 . 3 5 mm(1/4") 14~18 B (Liquid) ø9 .
  • Page 28: Cutting/Flaring The Pipes

    Cutting/Flaring the pipes 1 . Make sure that you have the required tools available . (pipe cutter, reamer, flaring tool and pipe holder) 2 . If you wish to shorten the pipes, cut it with a pipe cutter, taking care to ensure that the cut edge remains at a 90° angle with the side of the pipe .
  • Page 29: Performing Leak Tests

    Performing leak tests LEAK TEST WITH NITROGEN (before opening valves) In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R-410A, it’s responsable of installer to pressurize the whole system with nitrogen (using a cylinder with pressure reducer) at a pressure above 40 bar (gauge) .
  • Page 30: Refrigerant Pipe Work

    Refrigerant pipe work Insulating the pipes Once you have checked that there are no leaks in the system, you can insulate the piping and hose . 1 . To avoid condensation problems, place an insulator around each refrigerant pipe . • When insulate the pipe, be sure to overlap the insulation .
  • Page 31 Installing an oil trap Check the following list and install an oil trap . f Install an oil trap only when the outdoor unit is at a higher level than the indoor unit . f Based on cooling operation, install it on the gas side pipe only . f Install the oil trap only in between the outdoor unit and the first branch joint and it should be installed at every 10 m .
  • Page 32: Using Stop Valve

    Using stop valve To Open the Stop Valve 1 . Open the cap and turn the stop valve counterclockwise by using a hexagonal wrench . 2 . Turn it until the axis is stopped . Service port • Do not apply excessive force to the stop valve and always use special instruments .
  • Page 33: Interface Module Installation (Optional)

    Interface module Installation (Optional) Accessories (Interface module : MIM-B13D) Interface module Interface module Interface module Installation Manual Case Cable-tie power cable communication cable 1 . Fix the case at with bolts on the side of the control box in the outdoor unit . (See the picture) 2 .
  • Page 34: Pump Down Procedure

    Pump down Procedure Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area . 1 . Remove the cap from the low pressure side . 2 . Turn the low pressure side valve clockwise to close and connect a pressure gauge (low pressure side) to the service valve, and open the valve again .
  • Page 35: Checking Correct Grounding

    Checking correct grounding If the power distribution circuit does not have a grounding or the grounding does not comply with specifications, an grounding electrode must be installed . The corresponding accessories are not supplied with the air conditioner . 1 . Select an grounding electrode that complies with the specifications given in the illustration .
  • Page 36: Testing Operations

    Testing operations 1 . Check the power supply between the outdoor unit and the auxiliary circuit breaker . f 1 phase power supply : L, N f 3 phases power supply : R,S,T,N 2 . Check the indoor unit . 1) Check that you have connected the power and communication cables correctly .
  • Page 37 6 . View Mode : When the K4 switch is pressed, you can see information about our system state as below . Short Display contents SEG1 SEG2 SEG3 SEG4 Unit push Order frequency Hundreds' digit Tens' digit Unit digit Current frequency Hundreds' digit Tens' digit Unit digit The number of current indoor units...
  • Page 38 Testing operations 7 . DIP switch option 1 2 3 4 1 2 3 4 SW507 SW508 f DIP switch(SW507) option On (default) Switch 1 Auto address Manual address Switch 2 Disable snow prevention control Enable snow prevention control Switch 3 Silence Mode option Switch 4 ❋...
  • Page 39: Commission Delegated Regulation (Eu) No 626/2011

    COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Electronics Samsung Electronics Samsung Electronics Supplier's name Co., Ltd. Co., Ltd. Co., Ltd. Model name AC090FB4DEH/ AC100FB4DEH/ AC100FB4DEH/ (Indoor/Outdoor) AC090FCADEH AC100FCADEH AC100FCADGH Sound Power Level dB(A)
  • Page 40 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Electronics Samsung Electronics Samsung Electronics Supplier's name Co., Ltd. Co., Ltd. Co., Ltd. Model name AC090FB4PEH/ AC100FB4PEH/ AC100FB4PEH/ (Indoor/Outdoor) AC090FCAPEH AC100FCAPEH AC100FCAPGH Sound Power Level dB(A)
  • Page 41 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC100FB4FEH/ AC090FBMSEH/ AC100FBMSEH (Indoor/Outdoor) AC100FCAFEH AC090FCASEH AC100FCASEH Sound Power Level dB(A) 60/68 65/68 65/69 (Indoor/Outdoor) Refrigerant name...
  • Page 42 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Electronics Samsung Electronics Samsung Electronics Supplier's name Co., Ltd. Co., Ltd. Co., Ltd. Model name AC090FBMDEH/ AC100FBMDEH/ AC100FBMDEH/ (Indoor/Outdoor) AC090FCADEH AC100FCADEH AC100FCADGH Sound Power Level dB(A)
  • Page 43 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC090HBMDKH/ AC090HBMDKH/ AC100HBMDKH/ (Indoor/Outdoor) AC090HCADKH AC090HCADNH AC100HCADKH Sound Power Level dB(A) 61/68 61/68 61/69 (Indoor/Outdoor) Refrigerant name...
  • Page 44 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC100HBMDKH/ AC120HBMDKH/ AC120HBMDKH/ (Indoor/Outdoor) AC100HCADNH AC120HCADKH AC120HCADNH Sound Power Level dB(A)
  • Page 45 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC071HBMPKH/ AC090HBMPKH/ AC100HBMPKH/ (Indoor/Outdoor) AC071HCAPKH AC090HCAPKH AC100HCAPKH Sound Power Level dB(A) 56/65 59/65 61/66 (Indoor/Outdoor) Refrigerant name...
  • Page 46 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC100HBMPKH/ AC120HBMPKH/ AC120HBMPKH/ (Indoor/Outdoor) AC100HCAPNH AC120HCAPKH AC120HCAPNH Sound Power Level dB(A)
  • Page 47 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. Model name AC100JNCDEH/EU AC100JNCDEH/EU AC120JNCDEH/EU (Indoor/Outdoor) AC100JXADEH/EU AC100JXADGH/EU AC120JXADEH/EU Sound Power Level dB(A) 60/69 60/69 62/70 (Indoor/Outdoor) Refrigerant name...
  • Page 48 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Samsung Supplier's name Electronics Co.. Ltd. Model name AC120JNCDEH/EU (Indoor/Outdoor) AC120JXADGH/EU Sound Power Level dB(A) 62/70 (Indoor/Outdoor) Refrigerant name R-410A 2088 SEER 5 . 7 Energy efficiency class (SEER)
  • Page 49 COMMISSION DELEGATED REGULATION (EU) No 626/2011 [Spanish-ES] [French-FR] [Italian-IT] [Portuguese-PT] REGLAMENTO DELEGADO RÈGLEMENT DÉLÉGUÉ (UE) REGOLAMENTO DELEGATO (UE) REGULAMENTO DELEGADO (UE) No 626/2011 DE LA No 626/2011 DE LA COM- N. 626/2011 DELLA COMMIS- (UE) N.o 626/2011 DA ⅰ COMISSÃO COMISIÓN MISSION SIONE...
  • Page 50 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [German-DE] [Greek-EL] [Dutch-NL] [Polish-PL] GEDELEGEERDE VERORDEN- ROZPORZĄDZENIE DE- DELEGIERTE VERORDNUNG ΚΑΤ’ ΕΞΟΥΣΙΟΔΌΤΗΣΗ ⅰ ΚΑΝΟΝΙΣΜΌΣ (ΕΕ) αριθ. ING (EU) VAN DE COMMISSIE LEGOWANE KOMISJI (UE) nr (EU) Nr . 626/2011 DER 626/2011 ΤΗΣ...
  • Page 51 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Hungarian-HU] [Czech-CS] [Slovak-SK] [Romanian-RO] NAŘÍZENÍ KOMISE V A BIZOTTSÁG 626/2011/ DELEGOVANÉ NARIADENIE REGULAMENT DELEGAT (UE) ⅰ PŘENESENÉ PRAVOMOCI EU FELHATALMAZÁSON KOMISIE (EÚ) č. 626/2011 NR. 626/2011 AL COMISIEI ALAPULÓ RENDELETE (EU) č. 626/2011 Termékismertető...
  • Page 52 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Bulgarian-BG] [Croatian-HR] [Slovenian-SL] [Danish-DA] KOMMISSIONENS DELEGE- DELEGIRANA UREDBA DELEGIRANA UREDBA ДЕЛЕГИРАН РЕГЛАМЕНТ (ЕС) ⅰ REDE FORORDNING (EU) Nr. KOMISIJE (EU) št. 626/2011 № 626/2011 НА КОМИСИЯТА KOMISIJE (EU) br. 626/2011 626/2011 Podatkovna kartica izdelka Informacijski list proizvoda...
  • Page 53 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Swedish-SV] [Finnish-FI] [Estonian-ET] [Latvian-LV] DELEGOITU KOMISSION KOMMISSIONENS KOMISJONI DELEGEERITUD KOMISIJAS DELEĢĒTĀ ⅰ ASETUS (EU) N:o DELEGERADE FÖRORDNING MÄÄRUS (EL) nr 626/2011, REGULA (ES) Nr. 626/2011 626/2011, (EU) nr 626/2011 Ražojuma speciālā zīme Produktblad Tuoteseloste Tootekirjeldus (kliimasead- (gaisa kondicionētāju...
  • Page 54 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Lithuanian-LT] [Serbian-SR] KOMISIJOS DELEGUOTASIS REGLAMENTAS КОМИСИЈА ДЕЛЕГАТЕД УРЕДБА (ЕС) № ⅰ (ES) Nr . 626/2011 626/2011 Gaminio vardinių parametrų lentelė ПРОИЗВОДА ФИЦХЕ (енергетског ⅱ (oro kondicionierių energijos vartojimo означавања...
  • Page 55 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Spanish-ES] 1 . Las fugas de refrigerante contribuyen al cambio climático . Cuanto mayor sea el potencial de calentamiento global (GWP) de un refrigerante, más contribuirá a dicho calentamiento su vertido a la atmósfera . Este aparato contiene un líquido refrigerante con un GWP igual a [xxx] .
  • Page 56 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [German-DE] 1 . Der Austritt von Kältemittel trägt zum Klimawandel bei . Kältemittel mit geringerem Treibhauspotenzial tragen im Fall eines Austretens weniger zur Erderwärmung bei als solche mit höherem Treibhauspotenzial . Dieses Gerät enthält Kältemittel mit einem Treibhauspotenzial von [xxx] .
  • Page 57 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Hungarian-HU] 1 . A hűtőfolyadék szivárgása hozzájárul a globális felmelegedéshez . Minél kisebb egy hűtőfolyadék globális felmelegedési potenciálja (GWP-je), annál kevésbé járul hozzá a globális felmelegedéshez, ha a légkörbe kerül . A készülékben található hűtőfolyadék GWP-je [xxx] .
  • Page 58 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Bulgarian-BG] 1 . Изпускането на хладилен агент допринася за изменението на климата . Хладилен агент с по-нисък потенциал за глобално затопляне (ПГЗ) би допринесъл по-малко за глобалното затопляне, отколкото хладилен агент с по-висок ПГЗ...
  • Page 59 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Swedish-SV] 1 . Läckage av köldmedium bidrar till klimatförändringen . Köldmedium med lägre global uppvärmningspotential (GWP) skulle vid läckare ge upphov till mindre global uppvärmning än ett köldmedium med högre GWP . Den här apparaten innehåller ett köldmedium med GWP motsvarande [xxx] .
  • Page 60 COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Lithuanian-LT] 1 . Šaldalo nuotėkis prisideda prie klimato kaitos . Jei šaldalo nutekėtų į atmosferą, mažesnį visuotinio atšilimo potencialą turintis šaldalas mažiau prisidėtų prie visuotinio atšilimo negu didesnį visuotinio atšilimo potencialą turintis šaldalas . Šiame prietaise yra skysto šaldalo, kurio visuotinio atšilimo potencialas yra [xxx] .
  • Page 61: Troubleshooting

    Troubleshooting The table below give indication about self diagnostic routine . Some of error code requires activities exclusively for Authorized Service Center . Outdoor unit If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. Error Code Meaning Remarks...
  • Page 62 Error Code Meaning Remarks 1 . Check if the service valve is open 2 . Check for refrigerant leakage(pipe connections, heat exchanger) and charge refrigerant if necessary E422 Blockage detected on high pressure pipe 3 . Check if there's any blockage on refrigerant cycle(indoor unit/outdoor unit) 4 .
  • Page 63 Troubleshooting Error Code Meaning Remarks E484 PFC Overload (Over current) Error Check Outdoor Inverter PBA . E485 Error on input current sensor of inverter 1 (Short or Open) E500 IPM over heat error on inverter 1 Check Outdoor Inverter PBA . E508 Smart install is not installed E554...
  • Page 64 940*330*1210 mm RC140DHXEB 88 . 0 . kg 940*330*1210 mm RC140DHXGA 91 . 0 . kg 940*330*1210 mm AC090FCAPEH/EU 72 . 0 . kg 940*330*998 mm AC100FCAPEH/EU 88 . 0 . kg 940*330*1210 mm AC100FCAPGH/EU 91 . 0 . kg...
  • Page 65 MEMO...
  • Page 66 SAMSUNG ELECTRONICS CO . , LTD . 107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea 62218 Samsung Electronics (UK) Ltd, Euro QA Lab . Blackbushe Business Park . S axony Way, Yateley, Hampshire . G U46 6GG United Kingdom "AEEE Yönetmeliğine Uygundur"...