Samsung AC090FCAPEH Installation Manual page 13

Table of Contents

Advertisement

3 Phase
Type of
Model
outdoor
Outdoor Unit
Indoor Unit
unit
AC100FCADGH AC100FB4DEH
NS1004DXEA
RC100DHXGA
NS100SDXEA
AC120HCADNH AC120HBMDKH 50/60 380-415
A
AC100HCADNH AC100HBMDKH 50/60 380-415
AC090HCADNH AC090HBMDKH 50/60 380-415
AC100JXADGH
AC100JNCDEH
AC120JXADGH
AC120JNCDEH
AC100FCAPGH
AC100FB4PEH
RC100PHXGA
NS1004PXEA
NS1254DXEA
RC125DHXGA
NS125SDXEA
B
RC125PHXGA
NS1254PXEA
NS1404DXEA
RC140DHXGA
NS140SDXEA
AC140HCADNH AC140HBMDKH 50/60 380-415
AC140JXADGH
AC140JNCDEH
RC140PHXGA
NS1404PXEA
RC180DHXGH
NS180HHXEH
RC180DHXGG
NS180HHXEG
C
AC140HCAPNH AC140HBMPKH 50/60 380-415
AC120HCAPNH AC120HBMPKH 50/60 380-415
AC100HCAPNH AC100HBMPKH 50/60 380-415
1 . Voltage range
f Units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above
f
NOTE
listed range limits
2 . Maximum allowable voltage variation between phases is 2% .
3 . Wire size & type must comply with the applicable local and national code .
f Wire size : Based on the value of MCA .
f
f Wire type : 60245 IEC57(IEC) or H05RN-F(CENELEC) grade or more .
f
4 . MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) .
5 . MCA represents maximum input current .
MFA represents capacity which may accept MCA
❋ ❋ Abbreviations
f MCA : Min . Circuit Amps . (A)
f
f MFA : Max . Fuse Amps . (A)
f
6 . This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or
equal to Ssc(*2) at the interface point between the user's supply and the public system . It is the responsibility
of the installer or user of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or
equal to Ssc(*2) .
[Ssc (*2)]
AC140HCADKH, AC140JXADEH
AC140HCADNH, AC140JXADGH
AC120HCADKH, AC120JXADEH
AC120HCADNH, AC120JXADEH
AC100HCADKH, AC100JXADEH, AC100JXADEH1
AC100HCADNH, AC100JXADGH
Outdoor Units
Rated
Voltage Range
Hz
Volts
Min.
50
380-415
342
50
380-415
342
50
380-415
342
342
342
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
342
50
380-415
342
50
380-415
342
50
380-415
342
50
380-415
342
342
342
342
Model
AC140HCAPKH
AC140HCAPNH
Input Current [A]
Outdoor (Down_Amp)
Max.
Cooling
Heating
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
418
12
12
418
12
12
418
12
12
418
12
12
418
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
418
12
12
418
12
12
456 . 5
12
12
456 . 5
12
12
456 . 5
12
12
418
12
12
418
12
12
418
12
12
Ssc[MVA]
Model
2 . 7 15
AC090HCADKH
2 . 0 74
AC090HCADNH
2 . 9 96
AC120HCAPKH
2 . 0 64
AC120HCAPNH
3 . 3 65
AC100HCAPKH
2 . 0 86
AC100HCAPNH
3 . 1 57
AC090HCAPKH
2 . 0 75
AC071HCAPKH
Power Supply
Indoor
Total
MCA
MFA
0 . 7
12 . 7
12 . 7
15 . 0
0 . 7
12 . 7
12 . 7
15 . 0
1 . 5
13 . 5
13 . 5
15 . 0
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
1 . 0
13 . 0
13 . 0
15 . 0
1 . 0
13 . 0
13 . 0
15 . 0
1 . 0
13 . 0
13 . 0
15 . 0
2 . 0
14 . 0
14 . 0
15 . 4
1 . 0
13 . 0
13 . 0
15 . 0
1 . 0
13 . 0
13 . 0
15 . 0
2 . 0
14 . 0
14 . 0
15 . 4
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
1 . 0
13 . 0
13 . 0
15 . 0
2 . 9
14 . 9
14 . 9
16 . 4
2 . 9
14 . 9
14 . 9
16 . 4
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
Ssc[MVA]
2 . 9 54
2 . 0 75
3 . 0 2
2 . 0 83
3 . 4 39
2 . 0 76
3 . 2 99
3 . 3 29
13