TwoC_15_13_11_9_7_5_3_1
Threshold_Val_ME
FB_RetVal
IM_DB_No
No_used_IMs
New_Image
NOTICE!
Please note the permissible valuation of the block parameters. They are not mandatory
checked for plausibility. Incorrect inputs can cause unpredictable responses and incor-
rect functions.
SIPLUS RIC IEC on S7 V1.5
Functional description
Serves for fixing which TK's are transmitted also without change of the value or sta-
tus.
Set bits cause the transfer of the allocated information types also without change of
the value or status if the information was received with COT<20.
The numbers in the parameter name respond to the basis TK (without time).
Allocation of the parameter bits to the TK's
Bit
Bit 7
Bit 6
TK
15
13
Type
IT
MEc
Def.
0
0
With the default adjustment (B#16#0) only information with change of value or status
are transferred.
The nodal block offers the possibility for stabilization of measured values using
threshold procedure.
0: without any change of the measurands leads to forwarding.
>0 (e.g. 20): This value is used for direct or mathematical reachable threshold
In each cycle is a check and immediately reaction on direct threshold exceeding
The threshold processing is integrating – in a 1 sec interval the measured value dif-
ference to the last transmission is added up and transmitted spontaneously with the
mathematical achievement of the threshold.
For each measured value individual thresholds can be provided in a parameter data
block if assigned.
The function block is signaling as follows:
Positive values  ok
W#16#0000
ok, no fault
W#16#1000
ok, with reduced cycle (next_Info)
Negative values (16#8xxx)  fault
W#16#8102:
P_from_SL_Org = 0
W#16#8103:
Shared.Version (Job-ID) = wrong or
pointer wrong positioned
W#16#8112:
P_from_Application = 0
W#16#8113:
Application.Version (Job-ID) = wrong or
pointer wrong positioned
W#16#8301
IM-DB could not be installed
Reason could be insufficient working memory
W#16#8302
Image-DB full
Info could not be entered anymore
Number of the image-DB created from this block.
Number of the actually entered information in the image-DB.
The update of the image-DB is carried out automatically by incoming spontaneous,
requested or cyclic information.
Indicates that the number of information in the image-DB has been increased within
this OB1-cycle.
Page 15 of 28
Bit 5
Bit 4
Bit 3
Bit 2
11
9
7
MEb
MEa
BO
ST
0
0
0
I IA CE
Bit 1
Bit 0
5
3
1
DP
SP
0
0
0