Figure 2-4 Removing the Antenna Feeder Jumper Cable
3. Install a new cable.
a. Install the new RF cable with both ends connected to the proper interfaces in
accordance with the previously-recorded connection information.
b. Waterproof the RF connectors on two ends with one layer of insulation tape, three
layers of waterproof clay, and three layers of anti-ultraviolet tapes.
c. Check whether the cable can send and receive RF signals properly.
l
l
d. Paste a label on the new cable.
The label content should be consistent with that on the faulty one.
4. Notify the
5. Handle the faulty RF cable.
a. Put the faulty cable into a moisture-proof antistatic bag, mark the cable type and
fault information on a label, and then stick the label on the bag.
b. Put the bag containing the faulty cable into a carton, and stick the same label on
the carton, providing necessary information for cable repair.
SJ-20141127113509-004|2014-11-17 (R1.0)
Yes → The cable is connected properly. Go to the next step.
No → Troubleshoot the fault and connect the cable again, or contact ZTE
technical support.
OMC
administrator to unblock the cells corresponding to this site.