Grundfos STC Series Installation And Operating Instructions Manual

Grundfos STC Series Installation And Operating Instructions Manual

Shower pump

Advertisement

Grundfos.bk Page 1 Wednesday, September 3, 2008 1:36 PM
GRUNDFOS INSTRUCTIONS
Shower pump
Installation and operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Grundfos STC Series

  • Page 1 Grundfos.bk Page 1 Wednesday, September 3, 2008 1:36 PM GRUNDFOS INSTRUCTIONS Shower pump Installation and operating instructions...
  • Page 2 Grundfos.bk Page 2 Wednesday, September 3, 2008 1:36 PM Declaration of Conformity We Grundfos declare under our sole responsibility that the products SSL, STL, STC, SSR, STR, SSP, STP, SSN and STN, to which this declaration relates, are in conformity with the Council Directives on the approximation of the laws of the EC Member States relating to —...
  • Page 3: Table Of Contents

    These installation and operating instructions apply to the Do not allow any solder flux to come into contact with any of Grundfos Shower Pumps, types STL, SSL, STC, STR, SSR, STP, the plastic parts of the pump. SSP, STN and SSN.
  • Page 4: Positioning The Pump

    Grundfos.bk Page 4 Wednesday, September 3, 2008 1:36 PM 4. Positioning the pump 6. Cold-water supply Select a position for installing the pump which Do not connect the pump directly to the water affords easy access for subsequent servicing mains supply.
  • Page 5: Electrical Connections

    Grundfos.bk Page 5 Wednesday, September 3, 2008 1:36 PM 8. Electrical connections Ensure compliance with IEE Regulations. Observe colour coding as follows: Warning • Brown to terminal L. The pump must be earthed. • Blue to terminal N. The pump must be connected to an external...
  • Page 6: Negative-Head Pumps

    Grundfos.bk Page 6 Wednesday, September 3, 2008 1:36 PM 10. Negative-head pumps • Ensure an adequate head of water and non-restrictive make- up pipework. Pump types: STN, SSN and STL 2.0 CN. Inadequate feed head will cause pump cavitation, unstable water temperature, noise and ultimately pump and seal 10.1 General...
  • Page 7: Fault Finding Chart

    Grundfos.bk Page 7 Wednesday, September 3, 2008 1:36 PM 11. Fault finding chart Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on. Fault Possible cause Remedy 1.
  • Page 8: Fault Finding, Negative-Head Pumps (Stn, Ssn And Stl 2.0 Cn)

    Grundfos.bk Page 8 Wednesday, September 3, 2008 1:36 PM 11.1 Fault finding, negative-head pumps (STN, SSN and STL 2.0 CN) Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on.
  • Page 9: Technical Data

    Grundfos.bk Page 9 Wednesday, September 3, 2008 1:36 PM 12. Technical data Pump type Data SSP 2.0 B SSP 3.0 B STP 1.0 B STP 1.5 B STP 2.0 B STP 3.0 B STP 4.0 B Supply voltage 1 x 230 V, 50 Hz...
  • Page 10 Grundfos.bk Page 10 Wednesday, September 3, 2008 1:36 PM Pump type Data STL 1.0 C STL 1.5 C SSL 1.4 C STL 2.0 C STL 2.0 CN Supply voltage (transformer) 1 x 230 V, 50 Hz Transformer output 29 VDC...
  • Page 11: Service

    1. Use the public or private waste collection service. inspected at least every 6 months. Replace as necessary to 2. If this is not possible, contact the nearest Grundfos company prevent leaks. or service workshop.
  • Page 12 Grundfos.bk Page 12 Wednesday, September 3, 2008 1:36 PM System vent Shower outlet Cold-water storage tank 250 mm (10 inches) of at least 50 gallon below water level capacity Shower valve Cold-water supply min. 22 mm 22 mm Hot-water supply service min.
  • Page 13 Grundfos.bk Page 13 Wednesday, September 3, 2008 1:36 PM System vent Shower outlet Cold-water storage tank 250 mm (10 inches) of at least 50 gallon below water level Shower capacity valve Cold-water supply (Except STL 2.0 CN) min. 22 mm...
  • Page 14 Grundfos.bk Page 14 Wednesday, September 3, 2008 1:36 PM Shower valve Cistern Basin Bath System vent Negative Max. Cold-water Positive Cold-water storage tank supply of at least 50 gallon min. capacity 22 mm 22 mm Hot-water supply service min. gate...
  • Page 15 Grundfos.bk Page 15 Wednesday, September 3, 2008 1:36 PM Argentina Estonia Latvia Slovenia Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps Eesti OÜ SIA GRUNDFOS Pumps Latvia GRUNDFOS PUMPEN VERTRIEB Ruta Panamericana km. 37.500 Lote Peterburi tee 92G Deglava biznesa centrs Ges.m.b.H.,...
  • Page 16 Grundfos.bk Page 16 Wednesday, September 3, 2008 1:36 PM Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96787913 0908 Repl. 96787913 1207 www.grundfos.com...

Table of Contents