4. P341 Plumbers or GC4 Plumbers Reel (7mm dia.)

Rod Camera-End Retermination
Materials required:-
Rod Re-termination Kit
These instructions detail the re-termination procedures for both the P341 30m / 60m Plumbers
reels and GatorCam4 30m / 60m Plumbers reels. Ensure that you read and understand these
instructions in full before proceeding.
4.1.

93/RP3144Z10 Rod-end Re-termination Procedure

Remove the camera from the sonde spring, place out of the way.
Ensure that all damaged rod is removed from the reel. Cut off the damaged rod with the junior
hacksaw.
Pull out sufficient rod from the reel to facilitate the repair and lock the brake.
Copyright 2012 Radiodetection Ltd.– SPX Corporation. All rights reserved. Radiodetection is a subsidiary of SPX Corporation.
This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection
Ltd. We reserve the right to alter or amend any published specification without notice.
93/RP3144Z10
93/RP3144Z10
Remove the M3 x 4 grub screw
from the side of the rod cover,
using the 1.5mm AF Allen key.
This screw is secured with
Loctite 222.
Insert the M3 x 25mm caphead
screw into the grub screw socket
until it is hand-tight.
r