Operation manual
Features

Graphic display for easy user interface

Flexible power supply: 100V...240VAC / 50...60Hz, internal rechargeable battery
for up to 6 hours operation

2 inputs for CS flow / dew point sensors

up to 4 additional inputs for current clamps, pressure sensors and temperature
sensors

Auto-Detection of CS flow / dew point sensors

Complete configuration can be set through the user interface (no PC configura-
tion required)

USB interface for data upload to PC

PC software CS-Soft for data analyses (optional)

Data logger function for 1,000,000 values
DS 300-P English, V1.4, 07.15.09
DS 300-P
DS 300-P
1
0970 0010

Advertisement

loading
Need help?

Need help?

Do you have a question about the DS 300-P and is the answer not in the manual?

Questions and answers

Summary of Contents for CS Instruments DS 300-P

  • Page 1 Complete configuration can be set through the user interface (no PC configura- tion required)  USB interface for data upload to PC  PC software CS-Soft for data analyses (optional)  Data logger function for 1,000,000 values DS 300-P English, V1.4, 07.15.09 0970 0010...
  • Page 2 The device is destined exclusively for the described application. CS Instruments offers no guarantee for the suitability for any other purpose and is not liable for errors which may have slipped into this operating manual. They are also not liable for consequential damage resulting from the delivery, capability or use of this device.
  • Page 3 2400 g Probe connection and power supply DS 300-P is equipped with an internal rechargeable battery. This battery is intended to supply the system with power during power loss or for short term measurement where a mains supply is inconvenient. The charging time takes about 10 hours, where the battery life is around 6 hours.
  • Page 4 - ERR: Error occur during data logging. Logger module free memory in percentage , or CYCLE when logger memory in circular mode. The number indicates the terminal number, if it’s inverse this channel is set to be logged. 0970 0010 DS 300-P English, V1.4, 07.15.09...
  • Page 5 It tells how many item exist in level. the current menu, and which no. of item is currently selected If there is a “ > ” sign, it means we can go into the submenu of the current select DS 300-P English, V1.4, 07.15.09 0970 0010...
  • Page 6 HOUR -> MINUTE -> SECOND setup 3) After the SECOND setting and press the key to finalize the setup, or press to exit from the “Time and date setting” menu and without saving the new setting 0970 0010 DS 300-P English, V1.4, 07.15.09...
  • Page 7 To see another page, just press the arrow buttons on the key board . Operation in detail By pressing the <Enter> key the menu can be accessed. DS 300-P has following main menus: Logger operation Sensor settings System status and setting DS 300-P English, V1.4, 07.15.09...
  • Page 8 DS 300-P Logger operation DS 300-P includes a data logger that can record up to 1,000,000 measurement values. In order to configure the logger function and to activate/deactivate it, there are several functions available which are explained below: Set logging rate and...
  • Page 9 Sensor settings The following chapter describes the settings related to the sensor itself, which can be changed on the DS 300-P menu. For that purpose select in the menu the function “Sensor settings”. After the selecting “Sensor settings”, the next screen will show all detected flow/dew point sensors of terminal 1 and 2 and the selected analogue sensor of terminal 3 to 6.
  • Page 10 (absolute) has to be entered. Analogue sensor settings DS 300-P has up to 4 analogue input channels at terminal 3 to 6. These channels don’t have an automatic sensor detection, the sensors need to be manually selected. Following settings are available: ...
  • Page 11 Please refer to the connection chart and the connector pinning above. For loop pow- ered sensors, DS 300-P can supply current of up to 25 mA. For signal connection the optional 5 m cable 0553 0110 can be used, which comes with connector and open wire ends.
  • Page 12 0695 0122 Volume flow sensor VA 400-M, max version for DS 300-P, including 5 m cable 0699 0419 FA 410, dew point sensor, -80 .. +20 ºCtd, for DS 300-P, including meas- uring chamber and 5 m cable 0694 1886 Pressure sensor, 0 - 16 bar, for DS 300-P, 5 m cable...
  • Page 13 Other claims, especially those for dam- age occurring outside the instrument are not included unless responsibility is legally binding. DS 300-P English, V1.4, 07.15.09 0970 0010...
  • Page 14 VA 400/VA 410/DS 300-P and accessories CS Instruments GmbH as the manufacturer herewith declares that the above instru- ments and accessories belong to the category 9 (WEEE 2002/96/EC). Therefore the above instruments are not affected by the directive RoHS 2002/95/EC and by the ma- terial restriction.
  • Page 15 Flow and consumption meters VA 300, VA 400, VA 410, DS 300-P CS Instruments GmbH as the manufacurer herewith declares that the above mentioned pressure dew point, flow and consumption meters correspond with the requirements of the following guideline: Electromagnetic compatibility...
  • Page 16 CS Instruments (Asia) Co. Ltd. Room 31, Cambridge Plaza, Tower B 188 San Wan Road, N.T., Sheung Shui Hong Kong Tel. +86 (0) 755 – 8619 3164 +86 (0) 755 – 8619 3165 E-Mail sales@cs-instruments.com.hk www.cs-instruments.com.hk 0970 0010 DS 300-P English, V1.4, 07.15.09...