17.10 Zoomingadc™ Benefits - Semtech SX8724SEVK User Manual

Evaluation kit for sx8724s data acquisition system
Table of Contents

Advertisement

ADVANCED COMMUNICATIONS & SENSING
17.10 ZoomingADC™ Benefits
Now that we zoomed on the signal, we can compare the zoom performances with and without the offset
compensation. To make a comparison do as follow:
Without Zoom (gain only)
1. On the graph, set the full scale view: right click on the panel and select Undo All Zoom/Pan option to reset
the display range to the default full scale range.
2. Set the configuration to Gain = 225 & no offset cancellation as in
section.
3. Then blow in the sensor tube (try to make the maximum signal span).
The signal span correspond to 31923–28599 = 3324 bits. The result should look like the picture below:
With Zoom (gain and offset)
Now set the parameters as defined in
result should look like the picture below:
The signal span is 11743–1374=10370 bits which corresponds to a 320% gain on the signal reading
allowing you to have more consistent readings.
ACS - Revision 1.0
© Semtech Corp.
Figure 41. Signal Span Using Rough Gain Setting
17.6.4. Final Gains Configuration
Figure 42. Signal Span Using Zooming Settings
May 2011
Evaluation Kit for SX8724S Data Acquisition System
3324 bits span
10'370 bits span
Page 49
SX8724SEVK
USER GUIDE
17.5.2. Rough Gain Configuration
(Gain 825, offset -1.58 x V
www.semtech.com
). The
REF

Advertisement