OpTIONAL THERMOSTATIC VALVE
The product can be equipped with a thermostatic valve to control the flow of air to combustion, which must be
installed BEFORE THE CLADDING IS COMPLETED.
Brief description of the optional thermostatic valve installation procedure:
• open the hearth door (Fig. 1)
• Remove it to make the job easier by sliding it off the pins (fig 2) and details on door inversion instructions or
leave it
• remove the two deflectors (A - Fig. 3),the top deflector, the sides (C - Fig. 3), the fire plane (B - Fig. 3).
• remove the screwed-in plate (D - Fig. 3) and the plate below (E - Fig. 4), also screwed-in, to access the
compartment housing the thermostatic valve.
14
Fig. 1
Fig. 3
C
D
INSTALLATION
B
A
Fig. 4
E
Fig. 2