Recipe
Data record
name
Comment
Sort order
Data medium
Standard screen
Current values can be downloaded from the Touch Panel to the PLC and vice
Transfer Data
versa, without having to store them on a data medium. This makes the startup
Record
phase of a process easier, for example. Similarly, transfer between the Touch
Panel and data medium is also possible.
Using the standard screen Selective Data Record Transmission (figure 8-3) it is
possible to
TP27, TP37 Equipment Manual
Release 01/00
Select a recipe from the list of configured recipes.
Enter the name of the new data record or the data record to
be edited.
Enter a comment in respect of the data record to be edited.
The comment entered is only accepted when the data
record is stored on the data medium. It is not accepted if
the data record is saved a second time. In this case, the
comment must be entered in the Edit window (refer to
figure 8-4 on Page 8-10).
Define the sort criteria for the list of data records. Select
from the following sort criteria:
unsorted,
alphabetic,
alphabetic reversed,
chronological,
chronological reversed.
Select one of the data media flash or module (memory
card) here.
Format the data medium using the Format list box.
transfer the current values from the PLC to the main memory of the Touch
Panel,
transfer the current values from the main memory of the Touch Panel to the
PLC,
load data records from data medium into the main memory of the Touch
Panel,
transfer data records from the main memory of the Touch Panel to data
medium.