Panduit VeriSafe VS-CKP14-6 Installation Instructions

Panduit VeriSafe VS-CKP14-6 Installation Instructions

Insulation-piercing connection kits, insulation-piercing connectors for verisafe avt sensor lead tapping on copper conductors

Advertisement

Quick Links

© Panduit Corp. 2018
PANDUIT VSC Series Insulation-Piercing Connectors are intended for use in simplifying
installation and connection of PANDUIT VeriSafe AVT Absence of Voltage Testers to phase
(run) conductors, per electrical code requirements, within the rated environmental and
operational limitations according to regulatory / safety standard certifications or listings.
Email:
techsupport@panduit.com
EU Website:
www.panduit.com/emea
EU Email:
emeatoolservicecenter
@panduit.com
VeriSafe Insulation-Piercing
Connection Kits
Insulation-Piercing Connectors for
VeriSafe AVT Sensor Lead Tapping on Copper Conductors
INSTALLATION INSTRUCTIONS
Models: VS-CKP14-6, VS-CKP4-000
TO REDUCE THE RISK OF INJURY, USER
MUST READ INSTALLATION INSTRUCTIONS
BEFORE ATTEMPTING TO INSTALL
NOTE: In the interest of higher quality and value, Panduit products are
continually being improved and updated. Consequently, pictures
may vary from the enclosed product.
NOTE: Updates to this Installation Instructions may be available. Check
www.panduit.com
www.panduit.com
for the latest version of this manual.
Panduit Europe • EMEA Service Center
Tel: +31 546 580 452 • Fax: +31 546 580 441
T-PMPI-322EN
Rev. 02 [10-2018]
Panduit Corp.
USA Technical Support
Tel: 800-777-3300

Advertisement

loading
Need help?

Need help?

Do you have a question about the VeriSafe VS-CKP14-6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panduit VeriSafe VS-CKP14-6

  • Page 1 © Panduit Corp. 2018 PANDUIT VSC Series Insulation-Piercing Connectors are intended for use in simplifying installation and connection of PANDUIT VeriSafe AVT Absence of Voltage Testers to phase (run) conductors, per electrical code requirements, within the rated environmental and operational limitations according to regulatory / safety standard certifications or listings.
  • Page 2: Safety Information

    INSTALLATION INSTRUCTIONS T-PMPI-322EN © Panduit Corp. 2018 Rev. 02 [10-2018] Models: VS-CKP14-6, VS-CKP4-000 Safety Information This installation instructions contains information and warnings which must be followed to ensure safe termination and operation of the Insulation-piercing Connectors and an AVT Device.
  • Page 3 INSTALLATION INSTRUCTIONS T-PMPI-322EN © Panduit Corp. 2018 Rev. 02 [10-2018] Models: VS-CKP14-6, VS-CKP4-000 Step-by-Step Installation Procedure (continued from page 2 of 4) 6. See FIGURE 3 and FIGURE 4: Inspect location of factory-tightened TERMINAL in each TAP WIRE port in connector.
  • Page 4 INSTALLATION INSTRUCTIONS T-PMPI-322EN © Panduit Corp. 2018 Rev. 02 [10-2018] Models: VS-CKP14-6, VS-CKP4-000 Step-by-Step Installation Procedure (continued from page 3 of 4) 9. See FIGURE 7: Insert a crimped, color-coded pair of AVT sensor leads into TAP WIRE terminals. 10. See FIGURE 7: Verify fully-inserted AVT sensor leads by verifying that “location mark” (STEP 3) is flush with the connector body at wire insertion port.

This manual is also suitable for:

Verisafe vs-ckp4-000