4.13.8

Machines that are mounted together with the driven machine and transported

4.13.8.1

Storing machines together with the driven machine

● Before mounting the machines, grease the free parts of the shaft extension, as well as all
● Fill the terminal boxes of the machines with a substance that will absorb moisture, e.g.
● Store the machines in a dry, dust-free room where the temperature is controlled.
See also
Storage conditions (Page 33)
4.13.8.2

Commissioning

● Remove the moisture-absorbing substance, such as Branogel, from the terminal boxes
See also
Commissioning after storage (Page 36)
4.13.9

Storage outdoors

If the machine is stored outdoors, then the following should additionally be observed:
● Provide protective cover against the effects of sun and rain. Air must freely circulate to
● Every two months check the following:
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016
other bare metal parts, such as mounting foot surfaces, flange surfaces, terminal box and
cover contact surfaces. Attach caps filled with roller bearing grease to the shaft output gland
to provide protection against dust and humidity.
Branogel.
before commissioning.
avoid condensation forming.
– Free parts of the shaft extension and other bare metal parts, e.g. mounting foot surfaces
or the flange faces, terminal box and cover contact surfaces must be greased.
– Caps filled with grease attached to the shaft output gland to provide protection against
the ingress of dust and moisture are still effective.
Preparations for use