Recommended Alignment Accuracy; Mounting The Output Elements; Table 5-1 Recommended Alignment Accuracy; Table 5-2 Overall Flatness Of The Installation Surfaces - Siemens LOHER CHEMSTAR 1PS2 Operating Instructions And Installation

Induction motor
Table of Contents

Advertisement

Assembly
5.5 Installing the machine
Note
Store the rotor locking device
Be sure to store the rotor locking device. It must be remounted for possible disassembly and
transport.
Details about the alignment accuracy can be found in the Section "Information about the
machine dimension drawing".
5.5.4

Recommended alignment accuracy

The alignment accuracy required depends essentially on the configuration of the overall
machine train. Observe the required alignment accuracy of the coupling manufacturer in all
cases when aligning the machine.
Table 5-1
To avoid stressing the motor feet, the overall flatness of the installation surfaces must satisfy
the values in the following table:
Table 5-2
If shims are necessary for height adjustment and to avoid stresses, make them out of
adequately sized pieces of flat rolled strip. Complete balancing of the rotor together with the
transmission element may be found necessary.
5.5.5

Mounting the output elements

Balance quality
The rotor has a squirrel cage rotor made of die-cast aluminum or a brazed copper rotor. The
rotor is dynamically balanced with half feather key as standard. With a different balancing
status the marking for the corresponding balancing status is made using an adhesive sticker.
50
Recommended alignment accuracy
Speed [
]
rpm
750
1500
3000
Overall flatness of the installation surfaces
Frame size
≤ 080
090 - 355
≥ 400
Parallel offset [mm]
0.09
0.06
0.03
Overall flatness of the installation surfaces
Angular offset [mm per 100 mm cou‐
pling diameter]
0.09
0.05
0.025
0.1 mm
0.2 mm
0.3 mm
LOHER CHEMSTAR 1PS2