Carrier 48HC 04-28 Controls, Start-Up, Operation And Troubleshooting page 108

Single package rooftop units with comfortlink controls version 3.x and puron (r-410a) refrigerant
Hide thumbs Also See for 48HC 04-28:
Table of Contents

Advertisement

ITEM
EXPANSION
SETPOINTS
OCSP
Occupied Cool Setpoint
UCSP
Unoccupied Cool Setpoint
OHSP
Occupied Heat Setpoint
UHSP
Unoccupied Heat Setpoint
GAP
Heat-Cool Setpoint Gap
STO.R
SPT Offset Range (+/- )
RH.SP
Space RH Occupied SP
RH.UN
Space RH Unoccupied SP
RH.DB
Space RH Deadband
RH.HB
Reheat Heat SP Deadband
ITEM
CONFIGURATION
DISP
DISPLAY CONFIGURATION
METR
Metric Display
LANG
Language Selection
PROT
Password Enable
PSWD
Service Password
TEST
Test Display LEDs
UNIT
UNIT CONFIGURATION
S.DLY
Startup Delay
U.CTL
Unit Control Type
T.CTL
Thermostat Control Type
FN.SW
Fan Status Switch
FL.SW
Filter Status Switch
FS.SW
Fire Shutdown Switch
RM.SW
Remote Occupancy Switch
SAT.T
SAT Settling Time
RAT.S
RAT Sensor Installed
RH.S
RH Sensor on OAQ Input
RH.SW
Space Humidity Switch
TCS.C
Temp Cmp Strt Cool Factr
TCS.H
Temp Cmp Strt Heat Factr
I.FAN
INDOOR FAN CONFIG
FTYP
Indoor Fan Type
NSPD
Number of Speeds
OC.FN
Fan On When Occupied
IDF.F
Shut Down on IDF Failure
FS.MX
Supply Fan Maximum Speed
FS.VN
Fan Speed - Ventilation
FS.AQ
Fan Speed - IAQ Override
APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)
Table G — Mode — Set Points
RANGE
55 to 80
65 to 95
55 to 80
40 to 80
2 to 10
0 to 5
30 to 100
30 to 100
2 to 20
- 5 to 5
Table H — Mode — Configuration
EXPANSION
No/Yes
0=English
1=Spanish
2=French
3=Portuguese
Disable/Enable
0000 to 9999
Off/On
10 to 600
2=Thermostat
3=Space Sensor
0=Adaptive
1=1 Stage Y1
2=2 Stage Y1
3=Digital
0=No Switch
1=Normal Open
2=Normal Closed
0=No Switch
1=Normal Open
2=Normal Closed
0=No Switch
1=Normal Open
2=Normal Closed
0=No Switch
1=Normal Open
2=Normal Closed
10 to 900
No/Yes
No/Yes
0=No Switch
1=Normal Open
2=Normal Closed
0 to 60
0 to 60 mins
0=1- SPEED
1=LEN VFD
2, 3, or 7
No/Yes
No/Yes
80 to 100
0 to 100
0 to 100
UNITS
DEFAULT
°F
78
°F
85
°F
68
°F
60
^F
5
^F
5
%
50
%
80
%
8
^F
2
RANGE
UNITS
DEFAULT
No
Enable
1111
Off
UNIT
sec
30
2
0
0
0
0: no FIOP
1: FIOP
0
sec
240
No
No
0
mins
0
0
0
1: SAV option
2
Yes
Yes
100
%
67
%
100
108
CCN TABLE/SUB-TABLE
SETPOINT CONFIGURATION
SET_PNT
CCN TABLE/
CCN POINT
SUB-TABLE
SERVICE
CONFIG.
DISPLAY
DISPUNIT
LANGUAGE
PASS_EBL
PASSWORD
(display only, not
DISPTEST
in table)
STARTDLY
CTL_TYPE
STATTYPE
FANSTCFG
FILSTCFG
SHTDNCFG
REMOCCFG
SAT_SET
RAT_SENS
RH_OAQ
HUMSTCFG
TCSTCOOL
TCSTHEAT
AFAN_CFG
FAN_TYPE
NUM_SPDS
OCC_FAN
FATALFAN
16
SPEEDMAX
FSPDVENT
FSPDAQOR
CCN POINT
OCSP
UCSP
OHSP
UHSP
HCSP_GAP
SPTO_RNG
SPRH_SP
SPRH_USP
SPRH_DB
RH_HSPDB
PAGE
NO.
16
16
16
16
16
16
16
16
17
17
17
17
17
17
17
17
17
17
19
19
19
19
19
20