MultiHop H3E-NB-KR Data Radio
®
Datasheet
®
The Sure Cross
wireless system is a radio frequency network with integrated I/O that operates in most environments to eliminate the need for
wiring runs. Wireless MultiHop data radio networks are formed around a MultiHop master and one or more slaves and extend the range of a Modbus
or other serial communication network.
For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website,
wireless
.
WARNING:
• Do not use this device for personnel protection
• Using this device for personnel protection could result in serious injury or death.
• This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition.
Important:
• Electrostatic discharge (ESD) sensitive device
• ESD can damage the device. Damage from inappropriate handling is not covered by warranty.
• Use proper handling procedures to prevent ESD damage. Proper handling procedures include leaving devices in their
anti-static packaging until ready for use; wearing anti-static wrist straps; and assembling units on a grounded, static-
dissipative surface.
Models
Models
Frequency
DX80DR2M-H3E-NB-KR
2.4 GHz ISM Band
Configuration Instructions
Setting Up Your MultiHop Network
To set up and install your wireless MultiHop network, follow these steps:
1. If your radios have DIP switches, configure the DIP switches of all devices.
2. Connect the sensors to the MultiHop radios if applicable.
3. Apply power to all devices.
4. If your MultiHop radio has rotary dials, set the MultiHop Radio (Slave) ID. If your MultiHop radio has no rotary dials, continue to the next
step.
5. Form the wireless network by binding the slave and repeater radios to the master radio. If the binding instructions are not included in this
datasheet, refer to the quick start guide or product manual.
6. Observe the LED behavior to verify the devices are communicating with each other.
7. Configure any I/O points to use the sensors connected to the Sure Cross devices.
8. Conduct a site survey between the MultiHop radios. If the site survey instructions are not included in this datasheet, refer to the product
manual.
Original Document
209529 Rev. A
• Wireless industrial I/O device with four thermocouple inputs, two NPN discrete inputs, one thermistor
input, and two NMOS discrete outputs
Flex Power
®
power options allow for 10 to 30 V dc, solar, and battery power sources for low power
applications.
• Self-healing, auto-routing RF network with multiple hops extends the network's range
• Serial and I/O communication on a Modbus platform
• Message routing improves link performance
• DIP switches select operational modes: master, repeater, or slave
• Built-in site survey mode enables rapid assessment of a location's RF transmission properties
• Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery within the
unlicensed Industrial, Scientific, and Medical (ISM) band
Power
Housing
10 to 30 V dc or
integrated battery (ships
IEC IP65; NEMA 4X
without the battery)
18 January 2019
www.bannerengineering.com/
I/O
Inputs: Two NPN discrete, four thermocouple, one thermistor
(internal)
Outputs: Two NMOS discrete
Serial interface: RS-232
209529

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sure Cross MultiHop H3E-NB-KR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Banner Sure Cross MultiHop H3E-NB-KR

  • Page 1 • Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery within the unlicensed Industrial, Scientific, and Medical (ISM) band www.bannerengineering.com/ For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website, wireless WARNING: • Do not use this device for personnel protection •...
  • Page 2: Configure The Dip Switches

    Sure Cross ® MultiHop H3E-NB-KR Data Radio 9. Install your wireless sensor network components. If the installation instructions are not included in this datasheet, refer to the product manual. For additional information, refer to one of the following documents: 152653 •...
  • Page 3 Sure Cross ® MultiHop H3E-NB-KR Data Radio Disable Serial If the local serial connection is not needed, disable it to reduce the power consumption of a data radio powered from the solar assembly or from batteries. All radio communications remain operational. Receiver Slots The number of receiver slots indicates the number of times out of 128 slots/frames the radio can transmit to its parent radio.
  • Page 4: Modbus Registers

    For MultiHop DX80DR* models, Banner recommends using BWA-UCT-900, an RS-485 to USB adapter cable with a wall plug that can power your 1 Watt MultiHop radio while you configure it. The adapter cable is not required when connecting to a DXM Controller.
  • Page 5: Modbus Register Configuration

    Sure Cross ® MultiHop H3E-NB-KR Data Radio Register (4xxxx) Output # Output Type Units I/O Range Terminals Min. Value Max. Value Discrete OUT 1 Discrete OUT 2 Temperature Parameters The following parameters are used to configure analog inputs involving temperature and are typically used to configure thermocouple or RTD inputs. Registers for Analog Parameters (4xxxx) Parameters IN 1 (3301-3320)
  • Page 6: Specifications

    For hazardous or non-hazardous locations, the replacement battery model number is BWA-BATT-001 (Xeno model number XL-205F). For non-hazardous locations only, the replacement battery model number is BWA-BATT-011. For pricing and availability, contact Banner Engineering. Specifications MultiHop 2.4 GHz Korean Radio Specifications Radio Range 2.4 GHz Compliance for Korean Radio Models...
  • Page 7 When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. Consult with Banner Engineering Corp. if the destination country is not on this list.
  • Page 8 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

Table of Contents