Seite 13
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

Advertisement

Table of Contents
loading

Summary of Contents for WilTec ARTICEL 61018

  • Page 1 Due to further developments, illustrations, functioning steps and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us. © by WilTec Wildanger Technik GmbH Seite 13 http://www.WilTec.de http://www.aoyue.eu...
  • Page 2 The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram.
  • Page 3 Contents Introduction  Product Introduction  Technical Data  User Guide  Requirement of Operation  Repairs and Maintenance  Troubleshooting  Exploded Drawing and Parts List  © by WilTec Wildanger Technik GmbH Seite 15 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 4: Product Introduction

    The multiple pressure and overload protection makes the machine run in a stable condition. The  whole machine adopts a scientific design and a considerate conception to guarantee an easy op- eration and maintenance. © by WilTec Wildanger Technik GmbH Seite 16 http://www.WilTec.de http://www.aoyue.eu...
  • Page 5: Technical Data

    Turn it clockwise to increase the air pressure and turn it coun - terclockwise to decrease. Note: always pull the plug and cut the compressor off from the power source before any kind of adjustments or repairs/maintenance are done. © by WilTec Wildanger Technik GmbH Seite 17 http://www.WilTec.de http://www.aoyue.eu...
  • Page 6: Repairs And Maintenance

    The compressor vessel must be tested every two years. Also check the outside. If there is any  rusty crashed spots on the tank or if the tank fails to pass the pressure experiment, the tank must be scrapped. © by WilTec Wildanger Technik GmbH Seite 18 http://www.WilTec.de http://www.aoyue.eu...
  • Page 7: Troubleshooting

    2.Clean and replace the air filter element able to increase 3.Air leakage 3.Check and eliminate 4.Valve clack malfunction or air leakage 4.Clean or replace 5.Piston rubber bowl wear and tear 5.Replace piston rubber bowl © by WilTec Wildanger Technik GmbH Seite 19 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 8: Exploded Drawing And Parts List

    EXPLODED DRAWING AND PARTS LIST © by WilTec Wildanger Technik GmbH Seite 20 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 9 Hexagon Socket Screws (flat point) M8X10 Ball Valve Right Case Pressure Switch Lap Hoop Y40 Pressure Gauge Hexagon Socket Head Cap Screws M5X150 Adjustable Oil-Water Separator Flat Gasket Safety Valve © by WilTec Wildanger Technik GmbH Seite 21 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 10 All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.