Technical specifications
Current consumption
Effective power loss
Permitted ambient conditions
Ambient temperature
1)
Relative humidity
Housing, dimensions and weight
Design
Housing material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Depending on which pluggable transceiver you use, the maximum ambient temperature
1)
can change, see section "Accessories (Page 19)".
7.3.2
240 VAC variant
The following technical specifications apply to the 240 VAC variant of the SCALANCE
XR328-4C WG (GE).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Combo ports
Quantity
Electrical connect-
ors
Slots for pluggable
transceivers
SCALANCE XR-300WG
Operating Instructions, 05/2017, C79000-G8976-C454-01
7.3 Technical specifications of the SCALANCE XR328-4C WG (GE)
During operation up to 3000 m 0 ℃ to +60 ℃
During storage
During transportation
During operation at 25 ℃
Rack
Metal
IP30
482.6 x 43.6 x 127 mm
2800 g
19" rack mounting
> 33 years
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Transmission speed
900 mA
21.6 W
-40 ℃ to +85 ℃
-40 ℃ to +85 ℃
≤ 95 % no condensation
24
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100/ 1000 Mbps
4
4
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100/ 1000 Mbps
4
SFP transceiver
1000 Mbps
Technical specifications
55