Required Exterior Clearances; Insufficient Makeup Air - State Water Heaters SANDBLASTER SBD30 150 Service Handbook

Self-cleaning induced draft multi flue commercial gas water heaters
Hide thumbs Also See for SANDBLASTER SBD30 150:
Table of Contents

Advertisement

SBN71-120 thru 85-390, SBD30-150/199 TANK TYPE COMMERCIAL

REQUIRED EXTERIOR CLEARANCES

Stoichiometric or theoretical complete combustion requires 10 cubic feet of air per 1,000
BTUH of gas supplied. The National Fuel Gas code also recommends an additional 2.5 cubic
feet of "excess" air. For information on minimum make-up air opening sizes for various
building installations, refer to the National Fuel Gas Code NFPA 54, ANSI Z223.1, Sec. 5.3
INSUFFICIENT MAKEUP AIR ........ NEGATIVE AIR PRESSURE .....DOWNDRAFTS