Test 7 - Inducer On, Prover Switch And Low Gas Pressure Switch Closed - State Water Heaters SANDBLASTER SBD30 150 Service Handbook

Self-cleaning induced draft multi flue commercial gas water heaters
Hide thumbs Also See for SANDBLASTER SBD30 150:
Table of Contents

Advertisement

SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL
TEST 7 – INDUCER ON, PROVER SWITCH AND LOW GAS PRESSURE SWITCH
CLOSED ....................NO IGNITOR OPERATION
Conditions:
Power on
Plugs in receptacles
Inducer on
24V at ignition board E1, Pin
10
No Power to IGNITOR
Note:LED Flash code
TEST 7
If.......
Continuity is not indicated between E4plug pin 2 to 4.
Continuity is present
Voltage is not present between E4, Pin 2 to ground
Voltage
s i
p
e r
s
e
t n
Voltage is not present between E4, Pin 4 to ground
Voltage is present
S
a t
e t
W
t a
r e
H
e
a
e t
Ashland City, Tennessee
GAS WATER HEATER SERVICE HANDBOOK
Voltage check and continuity check of hot surface IGNITOR
circuit
Continuity check - Power off- Plug removed from E4 receptacles.
Nominal 80 VAC check - Plug in E4- Power "On".
s r
©
2
0
0
7
CHECK E1PIN 10 TO
GROUND – 24 V.
CONTINUITY TEST E4
PLUG
then.......
Check wiring and connection from E4 plug to HSI receiving
plug...................Replace HSI Assembly
Resistance should be between 11 and 20 Ohms at a
temperature of 77°F
Replace ignition board
C
ontinue
Check wiring and plug connections to HSI.........Replace HSI
Note ignition board, Flash code LED.............HSI should work