SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL
TEST 2 – POLARITY CHECK
Conditions:
No hot water
Green "Power" LED is on.
Tank is more than 5° F below
temperature dial setting.
Red ignition control board diagnostic
LED is flashing 6 times between
pauses.
Red, diagnostic "Call for Heat" LED-
OFF.
TEST 2
115-125 VAC is not present
Voltage is present white (right terminal) to ground but not
black (center terminal) to ground
S
a t
e t
W
t a
r e
H
e
a
e t
Ashland City, Tennessee
GAS WATER HEATER SERVICE HANDBOOK
Polarity Check
Check from on/off switch center and white wire terminals to ground
s r
©
2
0
0
7
see Test 1.
reverse supply wire connections - polarity is
reversed.