DESCRIPTION
The SRM-22 shutter controller is designed
for controlling window shutters or other equip-
ment driven with single-phase 230 VAC motors.
It can control two shutters independently. Control
can be routed wirelessly from transmitters or an
EXTA LIFE controller or wired from shutter push
buttons. To use wired control, use two pairs of in-
puts (IN1 and IN2), which are configurable using
a mobile app. Inputs can operate in local or cen-
tral control modes. In both cases, dual and single
shutter buttons can be used. Thanks to duplex
communication between the controller and the
control unit the current position of the shutter,
i.e. closing level is shown in the mobile app.
Duplex communication also enables controller
parametrisation and remote transmitter addition
(without physical access to the receivers). The
frame coding encryption system provides se-
cure control which is of particular importance in
the case of window shutters and garage doors.
SRM-22 can be controlled using a control unit
and also using the EXTA LIFE system transmit-
ters. You can register more transmitters with a
receiver to enable shutter control from several
locations. The product is designed for installing
in switchgears using a TH35 bar. With remote
update functionality from the controller. To further
enhance the controller's functionalities, there is
programmable movement time for each shutter
and you can define up to four favourite settings.
FEATURES
● Controlling shutters or other devices driven
with single-phase 230 VAC motors.
● Independent control of two shutters/motors
● Compatible with EXTA LIFE system control-
ler and transmitters
● Duplex transmission enables information on
the current position of the shutter in the mo-
bile app,
● Maximum load 350 W (2 A) – class AC3 per
shutter,
● Programmable inputs (local or central con-
trol function),
● Single or double shutter button can be con-
nected for local and central control,
● Programmable movement time for each
shutter,
● 2 programmable "Favourite" settings for
transmitters and external inputs,
● Up to 4 programmable "Favourite" settings
for calling up from the app,
● 2 operating modes for work with transmit-
ters (local / central),
● Open - stop - close control from the app +
slider control.
Zamel Sp. z o.o. hereby declares that the
SRM-22 radio equipment type conforms
to Directive 2014/53/EU.
The symbol means selective collecting
of electrical and electronic equipment.
It is forbidden to put the used
equipment together with other waste.
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamel.com, e-mail: export@zamel.pl
TECHNICAL DATA
Rated power consumption 0.65 W – standby
Optical signalling of transmission/programming Yes - green STATUS LED
Maximum number of paired buttons* 96 pairs for the whole controller (both shutters)
Shutter movement signalling Yes - 4 red LEDs
Current shutter position information
Operation modes in co-operation with EXTA LIFE system
Operation modes in co-operation with an EXTA LIFE controller
Number of external outputs 4 (2 per shutter)
Co-operation with shutter buttons*
Operation modes for external input
Shutter movement time***
Relay contact parameters 4 × 5A/250VAC
Number of termination points 12 (conductor cross-section up to 2.5 mm2)
Operating temperature range -10 to +55°C
Enclosure protection rating IP20
* applies to the complete controller (i.e. the buttons assigned to shutters 1 and 2) with button type configured using
the EXTA LIFE mobile app
** with a single button only one "favourite" setting is called up
*** closing and opening times programmed separately
APPEARANCE
Power terminals
Input terminals (for connection of spring-action
shutter buttons) shutter-1 and shutter-2
Transmit / receive signalling / status
during programming operations
PROG. button - programming
LEDs for signalling number of shutter selected during
programming operation and movement direction of a
shutter during standard operation
Output terminals for connecting motor for shutter-1 (M1)
Output terminals for connecting motor for shutter-2 (M2)
Catalogue designation SRM-22
Rated supply voltage 230 VAC
Rated frequency 50 / 60 Hz
Transmission RF – ISM 868 MHz (868.50 MHz) band
Transmission mode duplex – 9600 bps
Maximum power 14 dBm (25 mW)
Encryption 128-bit key algorithm
Operating range max. 300 m in open areas
Yes – in EXTA LIFE mobile app (shutter closure
percentage + icon)
local, central, 2 "favourite" settings
transmitters
Open, stop, close / shutter closing level in percent
set using a slider, up to 4 "favourite" settings
Only spring-action shutter buttons, single or double
buttons
Local or central for the local mode and double shutter
button – 2 "favourite" settings can be called up**
Programmable from 1s to 10 minutes (Default time
120 s)
Maximum load 2 x 350 W (2 A) – class AC3
Single-phase 230 VAC with limit switches or overload
Supported motors
switches
Enclosure mounting TH35 bar
Dimensions Double module (2DIN) housing 90 x 35 x 66 mm
Weight 0.125 kg
OPERATION MANUAL
Antenna socket
plik: SRM-22_inst_ext_gb | modyfikacja: 30.05.2018

Advertisement

loading

Summary of Contents for Zamel exta life SRM-22

  • Page 1 ● Open - stop - close control from the app + programming operation and movement direction of a slider control. shutter during standard operation Zamel Sp. z o.o. hereby declares that the SRM-22 radio equipment type conforms Output terminals for connecting motor for shutter-1 (M1) to Directive 2014/53/EU.
  • Page 2: Operating Modes

    OPERATING MODES • To assign a Favourite position to a specific button: set the shutter closure rate with the slider, wait until the shutter reaches the set position, refresh the screen and then press and hold the selected Favourite field. After successful assignment, the defined value is shown inside the field. •...
  • Page 3: Operating Considerations

    PROGRAMMING THE TIME OF MOVEMENT FOR SHUTTERS CONFIGURING THE SECOND FAVOURITE POSITION CAUTION: You must correctly program the opening and closing times when controlling the shutter from the mobile app or when defining the 1. Open or close the shutter completely. 2.
  • Page 4 CLEARING ALL CONTROLLER MEMORY INPUT FUNCTIONALITY , (LOCAL 1, LOCAL 2) After clearing the SRM-22 receiver’s memory, all transmitters’ buttons are removed from the memory. Clearing the memory includes unpairing (removal) of the The inputs ▼ and ▲ are provided for wired control of SRM-22. LOCAL 1 input is provided for controlling the first shutter, and LOCAL 2 is for controlling receiver from an EXTA LIFE controller.
  • Page 5: Installation

    4. ZAMEL will review complaints in accordance with existing regulations.; 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract.