7. WIRING [Wiring Connection Diagram, Control Panel /LCD monitor Specifications]

7.4 Wiring Connection Diagram

1.Wiring Connection Diagram 1 (132WN, 145WN, 160WN, 460V Class)  ............... Page 51
2.Wiring Connection Diagram 2 (200WN, 240WN, 460V Class) ........................... Page 53
3.Wiring Connection Diagram 3 (400V Class, Inverter Staring)  ........................... Page 55

7.5 Control Panel /LCD monitor Specifications

Operating
Source Voltage
Starting Method
(1) Unload stop operation
Operating
Functions
(4) Dryer prestart
ECOMODE [
(7)
Display
(1) POWER light
Functions
(4) LOAD light
(Light)
(7) AUTO START light
(1) Control setting and function setting
Setting function
Display function
(1) Discharge pressure
(4 digit digital monitor)
(4) Load ratio
(7) Pressure setting
Display
(1) Monitor Display
Functions
Clock
‒ 
(LCD display)
Interstage Pressure
Loading hours
‒ 
Dis. Temp. 2
‒ 
2nd stage Air End Suction temp.
Load ratio
(2) Message Display
Inspection
Message
(3) Alarm/Shutdown Display
Alarm
Shutdown
(4) Function Setting Display
Model setting
Shutdown history
Operation data
(1) Operation output
No Voltage
(2) Alarm output
Terminal
(3) Shutdown output
IPI Auto Restart Circuit
(Note) Setting (1) : Selected on the instrument panel (from 1 to 5 seconds)
Setting (2) : 15 to 60 seconds
Unload Stop : Operated by unload stop key pad located lower on operation print board.
50
- △
Fixed Speed
...
(2) IPI restart (optional)
(5) Dual operation (optional)
]
Energy save operation
(2) START light
(5) REMOTE light
(2) Running hours
(5) Warning/Shutdown Code
Control Setting
‒ 
Oil pressure
‒ 
Number of load/unload
Oil Temp.
Hours before next maintenance
ON time
Auto Stop
IPI/retry
Setting/Connection Error
Malfunction
Warning history
Operating mode
Capacity control
make contact×1
...
make contact×1
...
make contact×1
...
20ms or less
Continues operation.
20ms to Setting (1)
Shutdown compressor (dis. air), restart automatically after Setting (2).
Setting (1) or more
Shutdown compressor.
460V (60Hz)
(3 contactors) VSD
Variable Frequency Drive
... 
(3) Remote operation
(6) Schedule operation
(3) SHUTDOWN MODE light
(6) AUTO light
(3) Discharge temperature
(6) Warning/Shutdown History
Discharge pressure
Operating hours
Dis. Temp. 1
Current
‒ 
Next maintenance
‒ 
OFF time
‒ 
Restart
Unload stop running
Reconnect Power
Scheduled operation
Detailes of shutdown history