Number Label; Specifications And Diagrams For The External Expansion Terminal - Roland LEF-300 Master Manual

Hide thumbs Also See for LEF-300:
Table of Contents

Advertisement

Main Specifications
Locations of the Power Rating and Serial Number Label

Specifications and Diagrams for the External Expansion Terminal

External Controller Connector
• General-purpose I/O interface
• Connector: 25-pin D-SUB connector
• Pin assignment
Pin number
IN/OUT
1
OUT
2
OUT
3
OUT
4
OUT
5
OUT
6
OUT
8
9
10
11
7, 12, 24
13, 25
14-23
90
Chapter 3 Appendix
Serial number
This is required when you seek maintenance, servicing,
or support. Never peel off the label.
Power ratings
Use an electrical outlet that meets the requirements for
voltage, frequency, and amperage given here.
Signal name
READY
BUSY
PAUSE
FINISH
ERROR
Reserve1
IN
ERROR
IN
ENTER
IN
Reserve1
IN
Reserve2
IN
N.C
+24V EXT
IN
GND EXT
Overview/function
Setup is complete and printing is possible.
Printing.
Printing is paused.
Output when switching between the READY and BUSY signals.
MotorError, ProtectMotorError, or temperature error.
Not used.
Informs the printer of the error status of the external device. An emergency
stop occurs when the printer receives the ERROR signal.
The printer receives the input of the [ENTER] key from an external source.
Not used.
Not used.
Not used.
External power supply input. Supply +24 V.
External power supply ground.

Advertisement