5.1
Operating modes
The 'Set mode' menu enables the different operating modes of the MultiCharger 1500 to be set up
and activated.
These settings should be made very carefully to avoid any potential damage to the vehicle connected
to the charger (e.g. connecting a charger in EPS 24V mode to a vehicle with a 12V electrical system
will cause harm to the vehicle).
5.1.1
Charging (CHRG) mode
This is a sub-item of the 'Set mode' menu and can be used to set the MultiCharger 1500 to battery
charging mode. The functioning of this operating mode is described in more detail in section 2.2.
5.1.2
EPS 12V mode
This is a sub-item of the 'Set mode' menu and can be used to set the MultiCharger 1500 to external
power supply mode. The functioning of this mode is described in more detail in section 2.3.
5.1.3
EPS 24V mode
This is a sub-item of the 'Set mode' menu and can be used to set the MultiCharger 1500 to 24V
external power supply mode. The functioning of this mode is described in more detail in section 2.3.
The charger can only be set to 'EPS 24V mode' if this has already been activated (see section 5.2).
5.1.4
EPS autostart mode
This is a sub-item of the 'Set mode' menu and can be used to set the MultiCharger 1500 to external
power supply mode with automatic battery voltage recognition. The functioning of this operating mode
is described in more detail in section 2.4.