Product Information Related To Ecodesign Regulation No 2015/1188 - Schwank deltaSchwank Series Technical Manual

Radiant tube heater with pneumatic gas-/air ratio control
Table of Contents

Advertisement

18 Product information related to Ecodesign
Regulation No 2015/1188
Fuel Natural gas / Propane
Values
Nominal heat input [kW] @ NCV
Minimum heat input [kW] @ NCV
Minimum heat input as percentage of
nominal heat input [%]
h
[%] @ GCV
Thermal 
at nominal heat input
h
[%] @ GCV
Thermal 
at minimal heat input
Radiant factor RF
[%] @ NCV
nom
at nominal heat input
Radiant factor RF
[%] @ NCV
min  
at minimal heat input
Auxiliary electricity consumption
at nominal heat input
Auxiliary electricity consumption
at minimal heat input
Heat output control type
Space heating emissions NOx @ GCV
[mg/kWh]
Seasonal energy efficiency [%]
NCV= Net calorific value
GCV = Gross calorific value
Tab 11:
Characteristic values energy performance deltaSchwank
310U
10,0
7,5
25%
86,8%
87,2%
80,6%
80,9%
el
[kW]
max
0,03
el
[kW]
max
0,03
modulating
modulating
60
98,2%
deltaSchwank
320U
625U
20,0
25,0
10,0
12,5
50%
50%
83,2%
83,0%
86,8%
85,9%
78,1%
80,3%
80,6%
82,2%
0,04
0,04
0,03
0,02
modulating
60
60
99,0%
98,9%
deltaSchwank
635U
950U
35,0
48,0
17,5
25,0
50%
48%
80,9%
82,3%
84,4%
84,6%
78,6%
83,7%
83,2%
82,0%
0,08
0,17
0,03
0,05
modulating
modulating
60
60
97,4%
97,6%
1260U
58,0
29,0
50%
83,1%
85,8%
80,9%
83,4%
0,29
0,11
modulating
60
99,0%
57