Rs 232 Protocol - TAG Heuer CHRONOPRINTER 520 Operating Instructions Manual

Table of Contents

Advertisement

10.1
General
ON-LINE and OFF-LINE data transmissions from the COMPUTER port of the CP520 respect the following
transmission format. This format always comprises 30 characters + CR under the RS232 protocol at 9600
bds.
1 or 2
Characters for Data String Identification
3
Characters for the ranking
2
Space
4
Characters for Competitor Number
1
Space
2
Characters for Timing Input Channel
1
Space
15
Characters for Time
1
<CR> = End of Data String
Characters not used in the transmission of any value are replaced with a space.
10.2
Data String Identification Characters
S
Creation of a new RUN
S
Split time
L
Lap time
T
Time recorded on one of the input channels
R
Calculated Net Time for a Competitor
T-
False Start or False Finish (time disassociated)
T*
Any time modified through manipulation of start number
T+
Any time used if manually input using RECALL - INSERT
T=
Any duplicated time using FUNCTION - DUPLICATE
TC
Any discarded time rejected using "0# in RECALL"
10.3
Examples of Data Strings produced by the CP 520
Times taken for Competitor #2 on input channels 1 and 2 (Manually)
T
2 M1 09:09:15.608000<CR>
T
2 M2 09:09:27.277000<CR>
Net time for Competitor #2, ranked in position 1 at 11.669 seconds.
R 1 2
10.4
Distinctive Characters Placed at the Start of Times Printed or Transmitted to PC
-
False Start of False Finish (disassociated times)
*
Competitor Number Modified with this time
+
Manually Entered Time using INSERT
=
Duplicated Time using function DUPLICATE
C
Any discarded time rejected using "0# in RECALL"
10. PROTOCOL RS 232
Data Transmission – Technical Description
11.669000<CR>
Page 22