USER INSTRUCTIONS VERY IMPORTANT! PLEASE MAKE SURE YOUR LOG BOOK ENCLOSED IS FILLED IN CORRECTLY. ALL CORGI REGISTERED INSTALLERS CARRY A CORGI ID CARD. BOTH SHOULD BE RECORDED IN YOUR CENTRAL HEATING LOG BOOK. YOU CAN CHECK YOUR INSTALLER IS CORGI REGISTERED BY CALLING ON 01256 372300 LIGHTING AND OPERATION BOILER IGNITION (fig.
system to avoid avoid frost damage. for which the boiler has been equipped, the efficient operation of the equipment approach the technical staff. and safety devices must be carried out exclusively by the authorized technical GAS CONVERSION staff. The boiler is supplied with an elec- CLEANING AND MAINTENANCE tric cable.
– Safety stat trip (fig. 5) If the safety thermostat trips, the red FLASHING RED LED SPIA ROSSA INTERMITTENTE "35°C" led will start flashing. In order to attempt a boiler restar t, rotate the selector knob to position ( ) and relea- se immediately, returning it to the sum- mer ( ) or winter (...
Page 6
ACTIVATING During functioning the lid of the regulator must be closed. – Selection of the operating mode The operating mode desired is selected by (reference keys grey colour) pressing the relative key with the correspon- ding symbol. The choice is displayed with the symbol Automatic functioning: the heating functions automatically according to the hea- ting programme entered.
Page 7
– On-line key If the rooms remain unused for a long period of time, the temperatu- re can be reduced with the on-line key, in this way saving energy. When the rooms are occupied again, press the on-line key to re-heat them. The current choice is displayed on the display: Fixed temperature heating Reduced temperature heating...
Page 8
– Heating/hot-water With the heating programme it is possible to set the switching times of the temperature for a service programme period of a week. The weekly programme consists of 7 daily programmes. One daily program- me allows 3 phases of heating. Each phase is defined by a starting time and a finishing time. The n.
Page 9
– Setting the time To set the current day of the week (1 = Monday/7 = Sunday) To set the current hour To set the current minute Once the hour is completed, the setting of the hour changes. With keys the current hour is regulated. Pressing these keys together, the regulation is speeded up in an increasing sense.
Page 10
– Error display Ignition lock-out Rotate selector CR/OFF/EST/INV/RESET on the boiler control panel to the release position ) to reset operation (fig. 3). If the lock-out re-occurs, call an authorised Service Centre. Safety thermostat trip Rotate selector CR/OFF/EST/INV/RESET on the boiler control panel to the release position ) to reset operation (fig.