Federal Communications Commission; International Protection Marking; Underwriters Laboratories And Canadian Standards Association; Features - Club Car Onward Operator's Manual

Hp 4-passenger lithium-ion
Table of Contents

Advertisement

FEDERAL COMMUNICATIONS COMMISSION

The battery charger is Federal Communications Commission (FCC) certified.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in an industrial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at their own expense.

INTERNATIONAL PROTECTION MARKING

The battery charger has an International Protection Marking (IP) certification of IP66.
The battery charger enclosure has an International Protection Marking (IP) certification of IP46.
The battery charger USB receptacle with the dust cover has an International Protection Marking (IP)
certification of IP66.
The AC supply connector has an International Protection Marking (IP) certification of IP20.
Note:
The AC supply connector is applicable for indoor use only. Keep all AC connections clean and
dry.
UNDERWRITERS LABORATORIES AND CANADIAN STANDARDS
ASSOCIATION
Listed by Underwriters Laboratories (UL) and Canadian Underwriters. Meets the criteria of the
Canadian Standards Association (CSA).

FEATURES

AC ELECTRICAL CORD AND PLUG

The AC electric cord has an equipment-grounding conductor and grounding type plug. The AC plug
must be connected to a correctly rated ground fault circuit interrupter (GFCI) receptacle with arc flash
protection. The receptacle must be installed and grounded in accordance with the National Electrical
Code, local codes, and local ordinances.
Two IC650 battery chargers can be on a single phase branch circuit protected by a 15A circuit breaker
or fuse.
Only one IC900 battery charger can be on a single phase branch circuit protected by a 15A circuit
breaker or fuse.
Use of an extension cord with the charger is not recommended. Precautions when the use of an
extension cord is necessary:
• The extension cord must accept a three-prong plug.
• The extension cord must be as short as possible and not exceed 12 ft (3.7 m).
• The extension cord must be a three-wire No. 12-AWG (American Wire Gauge) or No. 14-SWG
(British Standard Wire Gauge).
• Make sure that cords will not be stepped on, tripped over, or subject to damage or stress.
ONWARD HP 4-PASSENGER LITHIUM-ION
Operators Manual
TPCC01DL00EN019 (Edition A)
Battery Charger
5