Download Print this page

GRAUPNER G-BOOSTER 160 Manual page 57

Advertisement

Available languages

Available languages

54:RC2-MODE
Selecting the RC2 signal function
Standard value: OFF
OFF
= control only via RC1 (throttle)
SAFETY = additional safety switching function via RC2
SMOKE = switching function for a smoker valve
SPEED = speed control via RC2 and RC3 (flaps)
PITCH
= temperature control via RC2 and RC3 (pitch)
55:RC2-HOME
Adjusting the neutral RC2 signal position for the RC3 output
For some RC2 modes, you can define a neutral position for the servo here.
Standard value: 1.50 ms
56:FAILS-TIME
Adjusting the hold time for the RC1 signal in the case of a remote control failure (failsafe).
If the RC1 signal is out the range between the values defined at 51:RC1-TRIM.OFF and 53:RC1-
100%, a remote control failure (failsafe) is detected. During the time specified here, the JETRONIC
will automatically set the throttle to the value defined at 57:FAILS-THROTTL.
If the failsafe state persists after this time has elapsed, the jet engine is switched off automatically.
Standard value: 5 seconds
57:FAILS-THROTTL
Adjusting the thrust level in the case of an RC1 signal failure (failsafe)
Standard value: 20 %
58:AUX-MODE
Selecting the AUXiliary function / connection to the JETRONIC - AUX
OFF
= no function
AIRSPEED = airspeed sensor connected, 37:AIRSPEED-MAX active!
WARN-LED = Low rpm / overheating indicator with external LED
GRAUPNER G-BOOSTER 160 – Manual 1.91
26

Advertisement

Chapters

loading