Warranty - Stuart RE300 Assembly And Operating Instructions Manual

Rotary evaporators
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Spares
The following spare parts are available from your laboratory supplier.
(For a comprehensive parts list or circuit and wiring diagrams please
contact the Technical Service Department of Bibby Scientific Ltd
quoting model and serial number).
Cat. No.
Description
RE100/CO
Diagonal coil condenser (feed tube not included)
RE200/VC
Vertical coil condenser (feed tube not included)
RE200/CF
Cold finger condenser (feed tube and drain not included)
RE100/COP
Diagonal coil condenser plastic coated (feed tube not included)
RE200/VCP
Vertical coil condenser plastic coated (feed tube not included)
RE200/CFP
Cold finger condenser plastic coated (feed tube and drain not included)
RE200/CFD
Drain for cold finger condenser
RE100/VR
Feed tube
RE100/VT
Vapour tube for diagonal condenser
RE100/VT/CF
Vapour tube for vertical coil and cold finger condensers
RE100/VS
Vacuum seal
FD1L/4RE
Florentine flask 1000ml
FD1L/4REP
Florentine flask 1000ml plastic coated
RE100/RF/1L
Receiving flask 1000ml
RE100/RF/1LP Receiving flask 1000ml plastic coated
KCM29
Conical joint clip
JC35
Spherical joint clip

Warranty

Bibby Scientific Ltd warrants this mechanical and electrical
equipment to be free from defects in material and workmanship,
when used under normal laboratory conditions, for a period of three
(3) years. In the event of a justified claim Bibby Scientific will replace
any defective component free of charge.
This warranty does NOT apply if damage is caused by fire, accident,
misuse, neglect, incorrect adjustment or repair, damage by
installation adaptation, modification, fitting of non-approved parts or
repair by unauthorised personnel.
This warranty does not apply to the glassware or vacuum seal.
These products meet the applicable EC
harmonised standards for radio frequency
interference and may be expected not to
interfere with, or be affected by, other
equipment with similar qualifications. We
cannot be sure that other equipment used in
its vicinity will meet these standards and so we
cannot guarantee that interference will not
occur in practice. Where there is a possibility
that injury, damage or loss might occur if
equipment malfunctions due to radio
frequency interference, or for general advice
before use, please contact the Technical
Department of Bibby Scientific.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Re301Re302Re300pRe302pRe301p

Table of Contents