Care and maintenance
WARNING
Before doing any work on the machine, pull the plug out
of the socket. Leave the unit to cool down.
Check all connected cables and hoses on a regular basis. If
power tools are damaged, they must be immediately
removed from use. Do not use blocked nozzles.
Repairs must always be referred to a Weller-trained
specialist.
Use original replacement parts only.
Warranty
Claims by the buyer for physical defects are time-barred
after a period of one year from delivery to the buyer. This
does not apply to claims by the buyer for indemnification in
accordance with §§ 478, 479 BGB (German Federal Law
Gazette).
We shall only be liable for claims arising from a warranty
furnished by us if the quality or durability warranty has been
furnished by use in writing and using the term „Warranty".
The warranty shall be void if damage is due to improper use
and if the device has been tampered with by unauthorised
persons.
Technical Data
Repair station
Dimensions L x W x H
Weight
Mains supply voltage
Power consumption
Safety class
Air flow
Temperature range Top
Heater
Top heater
Bottom heater
Operating sound level
from 1 m distance
Compressed air con-
nection
oil-free, dry compressed
air
99 Washington Street, Melrose, MA 02176
WTQB 1000
(mm)
660 x 360 x 390
(inch)
25,98 x 14,17 x 15,35
(kg)
22
(V / Hz)
230 / 50
(W)
2300
I
l/min
6 - 35
°C
150 – 400°
°F
(W)
300
(W)
max. 2000
(dB (A))
62
bar
5,5 - 8
Test Equipment Depot - 800.517.8431
TestEquipmentDepot.com
Symbols
Caution!
Warning! Risk of burns!
Read the operating instructions!
Before performing work of any kind on the unit,
always disconnect the power plug from the
socket.
ESD-compatible design and ESD-compatible
workstation
CE mark of conformity
Disposal
Do not dispose of electric tools together with
household waste material! In observance of Eu-
ropean Directive 2012/19/EU on waste electrical
and electronic equipment and its implementation
in accordance with national law, electric tools that
have reached the end of their life must be collec-
ted separately and returned to an environmentally
compatible recycling facility.
Original declaration of conformity
Repair station
WTQB 1000
We hereby declare that the products described herein
comply with the following guidelines:
2006/42/EG, 2014/30/EU, 2011/65/EU
Applied harmonised standards:
DIN EN 60204-1: 2007-06
DIN EN 60335-1: 2012-10
DIN EN 60335-2-45: 2012-08
DIN EN 62233: 2008-11 / 2009-04
DIN EN 55014-1: 2012-05
DIN EN 55014-2: 2009-06
DIN EN 50581:2013-02
Besigheim, 2016-03-08
T. Fischer
Technical director