FRU Information and Sensor Data Records
Table 7-2 Sensor No. 3 +12V A_MON (continued)
Feature
Rearm mode
Hysteresis support
Threshold access support
Event message control
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
Reading Type
Lower Non-Critical, Critical and
Non-Recoverable thresholds
Upper Non-Critical, Critical and
Non-Recoverable thresholds

Table 7-3 Sensor No. 4 +12V B_MON

Feature
Sensor Name
Device
Sensor Type
Class
Sensor Owner LUN
Entity ID
Entity Instance
Rearm mode
Hysteresis support
Threshold access support
Event message control
122
Raw Value/Description
Interpreted Value
Auto
Readable/Settable
Readable/Settable
Entire Sensor only
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Unsigned
0xDB, 0xDA, 0xD9
(11.8260, 11.7720, 11.7180) Volts
0xF7, 0xF9, 0xFA
(13.3380, 13.4460, 13.5) Volts
Raw Value/Description
Interpreted Value
+12V B_MON
0x02
Voltage
0x01
Threshold
0x00
0x0A
Power Supply
0x60
Auto
Readable/Settable
Readable/Settable
Entire Sensor only
AXP 1410 Installation and Use (6806800H70F)