The following tracker manufacturers and types are approved with Canadian Solar framed bifacial double glass modules.
compatible
module type
tracker
ATI DuraTrack™HZ
CS3U-MB-AG
Tracking
CS3U-PB-AG
System(V3)
CS3U-MB-AG
NEXTracker NX
CS3U-PB-AG
Horizon
Arctech
CS3U-MB-AG
single-axis tracker
CS3U-PB-AG
Portrait two rows
CS3U-MB-AG
Soltec SF7 Single-
CS3U-PB-AG
Axis Tracker
CS3U-MB-AG
Soltec SF7 Single-
CS3U-PB-AG
Axis Tracker
The allowable maximum twist angle of the module is 0.5
degree.
Please contact the tracker manufacturer and Canadian Solar
Inc. technical support department for details in regard to
specific projects.

7.0 maIntenance

· Do not make modifications to any component of the PV
module (diode, junction box, plug connectors or others).
· Regular maintenance is required to keep modules clear of
snow, bird droppings, seeds, pollen, leaves, branches, dirt
spots, and dust.
· Modules with sufficient tilt (at least 15°), generally do not
require cleaning (rain will have a self-cleaning effect). If
the module has become soiled, it shall be washed with
water and a non-abrasive cleaning brush or sponge
during the cool part of the day. Do not scrape or rub dry
dirt away, as this may cause micro scratches.
EN-Rev IM/GN-BM-EN/1.0 Copyright © June 2018. Canadian Solar Inc.
mounting Hardware
Clamp Ear (V3)
Short Rail V2.3
(400 mounting holes position)
Rail part No:
20871, 21018, 20882, 20952, 20940
3438 mm rail
(bolting method /
M8 bolt + M8 plain washer
(O.D. = 24 mm) /
1155 mm holes position)
Rail drawing No:
CS2018002
2604 / 2592 mm rail
(Bolting method /
M6 bolt + M6 plain washer (O.D. =
18 mm) / 1300 mm + 400 mm holes
position)
Rail drawing No:
SF7-MR-04-009_Dr < UL1500 V >
SF7-MR-04-016 < 1500 V (IEC) or
1000 V (IEC / UL) >
3359 / 3347 mm long rail
(bolting method /
M8 bolt + M8 plain washer (O.D. =
24 mm) /
1155 mm holes position) Rail
Rail drawing No:
SF7-MR-06-014_Dr < UL1500 V >
SF7-MR-06-015_Dr < 1500 V (IEC) or
1000 V (IEC / UL) >
· Snow should be removed using a soft brush.
· Periodically inspect the system to check the integrity of
all wiring and supports.
· To protect against electric shock or injury, electrical or
mechanical inspections and maintenance should be
performed by qualified personnel only.
· Please refer to Standard Module Installation Manual
Annex of standard solar modules (Section Annex D:
Module Cleaning Guideline) for more information on
this topic.

amended edItIons and dates

· Rev 1.0 is released in June, 2018.
maximum load
Reference manual
(Pa)
(version no.)
Uplift load
DuraTrack HZ Solar
≤ 2400 Pa
Tracker Installation
Downforce load
Guide , (June 2017,
≤ 2400 Pa
Rev. B-03)
NEXTracker NX
Uplift load
Horizon 2.3.1 Short
≤2400 Pa
Rail Installation
Downforce load
Manual (PDM-
≤ 2400 Pa
000149)
Uplift load
SSMFIM-rev01
≤ 2400 Pa
( SkySmart-Module
Downforce load
Fixing Installation
≤ 2400 Pa
Manual )
Uplift load
≤ 1800 Pa
SF7QG-1500V-en,
Downforce load
revision 1.0
≤ 1800 Pa
Uplift load
≤ 2400 Pa
SF7QG-1500V-en,
Downforce load
revision 1.0
≤ 2400 Pa