Mounting Method: Bolting; Maintenance; Annex A: Mechanical And Electrical Ratings - Canadian Solar CS Series Installation Manual

Solar module
Table of Contents

Advertisement

6.1 MOUNTING METHOD: BOLTING

·Modules should be bolted to support structures through mounting holes located in the frame's back flanges only. Do
not drill additional holes or modify the module frame. Doing so will void the warranty.
·Each module must be securely fastened at a minimum of 4 points on two opposite sides, using the most inner
mounting holes. If additional wind loads are anticipated for this installation, additional mounting points should be
used. System designer and installer are responsible for load calculations and for proper support structure design.
·Modules should be bolted at the following hole locations depending on the configuration and load as verified by the
test method in IEC 61215:
Table 6-1: Authorized attachments for bolting method
Uplift load
2400 Pa
Downforce load ≤ 2400 Pa
Use 4 standard mounting holes (short side)
Bolting on
short
side frame
(except for 6X
series)
Mounting rails may run parallel or
perpendicularly to the short side frame
Use 4 standard mounting holes (long side)
Bolting on
long side frame
Mounting rails may run perpendicularly or parallel to the long side frame
6.2 SPECIFIC MODULE RANGES
Technical notes
·
For NewEdge module frames (NewEdge series: CS5A-xxxMX, CS6A-xxxPX and CS6P-xxxPX models), please refer
to the most updated IM/NEWE-EN technical note (INTERTEK & CSA certified).
· For CS5A-M-L laminate models only, floating clamped configuration should be used. Please refer to the most
updated IM/LAM-EN technical note (CSA certified)

7.0 MAINTENANCE

·
Regular maintenance is required to keep modules clear of snow, bird droppings, seeds, pollen, leaves, branches,
dirt spots and dust.
· If a module has a sufficient tilt (at least 15 ), it generally is not necessary to clean the modules (rainfall will have a
0
self-cleaning effect). When there is a noticeable buildup of soiling deposits on the module surface, wash the PV array
with water and a gentle cleaning implement (a sponge) during the cool part of the day. Dirt must never be scraped or
rubbed away when dry, as this will cause micro-scratches.
· If snow is present, a brush with soft bristles can be used to clean the surface of the module.
· Periodically inspect the system to make sure all wiring and supports stay intact.
· If you need electrical or mechanical inspection or maintenance, it is recommended to have a licensed, authorized
professional carry out the job to avoid hazards of electric shock or injury.
· Do not change the PV components (diode, junction box, plug connectors).

ANNEX A: MECHANICAL AND ELECTRICAL RATINGS

Standard Test Conditions are: irradiance of 1 kW/m , AM1.5 spectrum, and cell temperature of 25℃ (77℉).
The electrical characteristics are respectively within ± 10 percent or [0,+5W] of the indicated values for Isc, Voc and
Pmax. Specifications are subject to change without notice.
6
QUALITY I VALUE I INNOVATION
Uplift load ≤ 2400 Pa
2400 Pa ≤ Downforce load ≤ 5400 Pa
Use 4 standard mounting holes (short side).
An additional support bar should be placed
below the module.
Support bar
Mounting rails should run parallel to
the short side frame
2
EN-Rev 2.3 Copyright
20
12 Sep.
Canadian Solar Inc.
Table A-1: Certification map for CS-series photovoltaic modules
Certification
CS5A-M
CS5A-P
CS5P-M
CS5P-P
Body
CS5A-MX
150-190W
Intertek
150-190W
200-260W
200-240W
(CS5A-M only)
CSA
170-200W
165-195W
215-260W
Certification
CS6P-M
CS6P-PM
CS6P-P
CS6P-PE
Body
CS6P-MX
CS6P-MM
CS6P-PX
160-230W
160-230W
Intertek
160-230W
(CS6P-M only)
(CS6P-P only)
CSA
200-260W
225-270W
200-260W
Table A-2: Specifications for CS-series photovoltaic modules under STC
Operating
Operating
Maximum
Model Type
power
Voltage
current
(Vmp) <V>
Imp <A>
Pmax<W>
CS5E-20M
20
17.6
1.14
CS5E-22M
22
17.9
1.23
CS5E-24M
24
18.4
1.31
CS5E-25M
25
18.7
1.34
CS5H-43M
43
17.8
2.41
CS5H-45M
45
18
2.5
CS5H-47M
47
18.3
2.57
CS5H-50M
50
18.7
2.68
85
CS5C-85M
17.8
4.78
90
CS5C-90M
18
4.99
95
CS5C-95M
18.3
5.19
100
CS5C-100M
18.5
5.39
CS5A-150M
150.0
35.0
4.29
CS5A-155M
155.0
35.1
4.42
CS5A-160M
160.0
35.1
4.55
CS5A-165M
165.0
35.3
4.68
170.0
CS5A-170M/MX/M-L
35.6
4.78
175.0
CS5A-175M/MX/M-L
35.8
4.89
180.0
CS5A-180M/MX/M-L
36.1
4.99
185.0
CS5A-185M/MX/M-L
36.4
5.09
190.0
CS5A-190M/MX/M-L
36.6
5.19
195.0
CS5A-195M/MX/M-L
37
5.27
200.0
CS5A-200M/MX/M-L
37.4
5.35
CS5A-150P
150.0
34.6
4.33
CS5A-160P
160.0
34.8
4.60
CS5A-165P
165.0
34.9
4.73
CS5A-170P
170.0
35.2
4.83
CS5A-175P
175.0
35.4
4.94
CS5A-180P
180.0
35.7
5.04
CS5A-190P
190.0
36.2
5.25
CS5A-195P
195.0
36.6
5.32
EN-Rev 2.3 Copyright
20
12 Sep.
Canadian Solar Inc.
QUALITY I VALUE I INNOVATION
CS5E-M, CS5H-M,
CS5T-M
CS5A-M-L
CS6X-P
CS5C-M, CS5C-P
CS5E: 20-25W
CS5H: 43-50W
130-150W
170-200W
250-310W
CS5C-M: 85-100W
CS5C-P: 80-95W
CS6H, CS6E,
CS6A-P,
CS6A-PM,
CS6D,CS6C
CS6A-M
CS6A-PE
CS6A-MM
(-M/P)
160-190W
135-190W
CS6H: 20-26W
CS6A-PM:
CS6E: 45-60W
175-220W
CS6D: 60-75W
CS6A-MM:
CS6C: 120-145W
180-220W
Open Circuit
Short Circuit
Max. Series
Overall
Voltage
Current
Fuse Rating
Dimension
Voc <V>
Isc <A>
<A>
<mm>
21.9
1.23
22.2
1.31
3.00
620×28 ×25
4
22.4
1.41
22.6
1.43
22.2
2.57
22.3
2.67
5.00
630x542x25
22.4
2.75
22.6
2.86
22.1
5.12
22.3
5.34
10.00
12 3×547×35
1
22.4
5.52
22.5
5.74
43.3
4.69
43.6
4.80
43.8
4.91
1595X801X40
44.1
5.01
(standard Ed1)
or
44.3
5.12
1580 X808X40
44.4
5.23
10.00
(standard Ed2)
44.6
5.34
or
1589X795X22.5
44.6
5.46
(M-L only)
44.8
5.52
45
5.62
45.3
5.71
43.0
4.76
43.4
4.99
1595X801X40
43.7
5.09
(standard Ed1)
43.9
5.20
or
10.00
44.1
5.31
1580 X808X40
(standard Ed2)
44.2
5.41
44.4
5.61
44.6
5.70
CS6X-M
260-310W
CS6A-PX
160-210W
Weight
<Kg>
2.10
3.5
8.00
15.30
(standard)
or
17.00
(MX only)
or
15.5kg
(M-L only)
15.30
7

Advertisement

Table of Contents
loading