Sample Of Serial Number / Safety Label - Hearth & Home Quadra-Fire DISCOVERY-II-C Owner's Manual

Wood appliance automatic combustion control (acc)
Table of Contents

Advertisement

Discovery II
NOTE: Clearances may only be reduced by means approved by the regulatory
authority having jurisdiction
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
CAUTION
ATTENTION:
LISTED ROOM APPLIANCE, SOLID FUEL TYPE.
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
ALSO FOR USE IN MOBILE HOMES. (UM) 84
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
HUD . "For Use with Solid Wood Fuel Only"
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec
PREVENT HOUSE FIRES
Bois Solide Seulement"
Install and use only in accordance with
manufacturer's installation and operating
instructions. Contact local building or fire
Installez et utilisez en accord avec les instructions
officials about restrictions and installation
d'installation et d'opération du fabricant. Contactez le
inspections in your area. Do not obstruct
bureau de la construction ou le bureau des incendies au
the space beneath appliance.
sujet des restrictions et des inspections d'installation dans
WARNING - For Mobile Homes: Do not
votre voisinage. Ne pas obstruez l'espace en dessous de
install in a sleeping room. An outside
l'appareil.
combustion air inlet must be provided
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
and unrestricted while unit is in use. The
une chambre à coucher. Un tuyau extérieur de combustion
structural integrity of the mobile home
d'air doit être installé et ne doit pas être obstrué lorsque
floor,
ceiling
and
walls
must
be
l'appareil est en usage. La structure intégrale du plancher,
maintained. The appliance needs to be
du plafond et des murs de la maison mobile doit être
properly grounded to the frame of the
maintenue intacte. L'appareil de chauffage doit être fixé à
mobile home. Components required for
la charpente de la maison mobile. Les composants requis
mobile home installation: Outside Air Kit,
pour l'installation des maisons mobiles: Assemblage d'air
Part Number OAK-ACC..
extérieur, Numéro de Pièce OAK-ACC.
Refer to manufacturer's instructions and
Référez vous aux instructions du fabricant et des codes
local codes for precautions required for
locaux pour les précautions requises pour passer une
passing chimney through a combustible
cheminée à travers un mur ou un plafond combustibles, et
wall or ceiling and maximum offsets.
les compensations maximums.
Inspect and clean chimney frequently -
Inspectez et nettoyez la cheminée fréquemment. Sous
Under
Certain
Conditions
of
Use,
certaines conditions, il se peut que la créosote s'accumule
Creosote Buildup May Occur Rapidly.
rapidement.
Do not connect this unit to a chimney
Ne pas connecter cet appareil à une cheminée servant un autre
serving another appliance.
appareil.
Optional Blower, Part BK-ACC.
tVentilateur Optionnel, Pièce BK-ACC.
Electrical Rating: 115 VAC, 1.2 Amps, 60
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer
Route power cord away from unit. Do
le fil électrique au dessus ou en dessous de l'appareil.
not route cord under or in front of
7.75
DANGER: Il y a risque de décharge électrique.
appliance.
Déconnectez le fil électrique de la prise de contact avant
DANGER: Risk of electrical shock.
le service.
Disconnect
power
supply
before
Remplacez la vitre seulement avec une vitre céramique de
servicing.
5 mm disponible chez votre fournisseur.
Replace glass only with 5mm ceramic
N'élevez pas le feu. Bâtissez le feu de bois directement
available from your dealer.
sur l'âtre.
Do not use grate or elevate fire. Build
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau
wood fire directly on hearth.
de cheminée rougissent, vous surchauffez.
Do not overfire - if appliance or chimney
Opérez l'appareil seulement lorsque la porte de
connector glows, you are overfiring.
chargement est fermée. Ouvrez la porte seulement
Operate only with the fuel loading door
lorsque vous devez ajouter des combustibles dans le feu.
closed. Open only to add fuel to the fire.
FLOOR PROTECTION
:
PROTECTION DU PLANCHER:
Floor protector must be a 3/8 (9.5mm) inch
Le protecteur de plancher doit être d'un minimum de 3/8
inch (9.5mm) d'épaisseur, de matériel incombustible ou
min. thickness, non-combustible material or
équivalent, s'étendant du dessous de l'appareil de
equivalent, extending beneath heater and to
chauffage à l'avant, aux cotés et à l'arrière comme indiqué
front/sides/rear as indicated on the diagram
sur le diagramme suivant. Exception: Les protections
below. Exception: Non-combustible floor
incombustibles du plancher doivent s'étendre en dessous
protections must extend beneath the flue pipe
du conduit de cheminée lorsqu'installées avec une
ventilation à l'horizontale et s'étendre de 2 inches (51mm)
when installed with horizontal venting and
de chaque côté.
extend 2 inches (51mm) beyond each side.
Millennium
39"
Fuel loading door
minimum
8"
16" from glass
USA
Millennium 31-5/8" Min
Manufactured by:
Fabriqué par:
352 Mountain House Road, Halifax, PA 17032
www.quadrafire.com
ECO #
DATE
BY
2
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
:
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
Tested and
O-T L
Listed by
C
OMNI-Test Laboratories, Inc.
Report
/ Rapport
PRÉVENTION DES FEUX DE MAISON
0061WS066S
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or
blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced
clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or
Security DL double wall connector pipe. Must be equipped with a spark arrestor.
Apply double wall clearances below when installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.
INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FOOT VERTICAL OFF STOVE TOP
INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: 90
INSTALLATION: 90
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT* listed factory-built Class "A" chimney, or a masonry
chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of
unit, and the referenced clearances.
INSTALLATION: ALCÔVE - De six (6
cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48
minimum de 48 inches (1220mm) du haut de l'appareil, et des espaces libres alloués.
DOUBLE WALL PIPE
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED / VOIR LE FABRICANT POUR LES ESPACES LIBRES DES CONDUIT - PAS TESTÉ
203mm (8")
90
o
OFF TOP
203mm
203mm
UP & OUT CEILING CLEARANCE
(8")
(8")
Millennium
ESPACE LIBRE DU DESSUS DE
1243mm
L'APPAREIL AU PLAFOND AVEC 90
(49")
DE COURBURE
minimum
457mm (18")
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU
CANADA
PLAFOND
1041mm (41") minimum
2019
2020 2021 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
Made in U.S.A.
of US and
imported parts.
Fabriqué aux
31M-ACC-C
États-Unis-d'Amérique par des
pièces d'origine américaine et
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
pièces importées.
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
ITEM
PART NUMBER
1
7033-354
Serial No. / N° de série
R
Portland
Oregon USA
TESTED
TO:/ TESTÉ À:
US
HF
UL 1482-11 (R2015) , ULC S627-00.
3100 ACC Series
VENT SPECIFICATIONS:
A
B
C
D
E
F
15.25 (387) 11.75 (298) 25.5 (648)
16 (406)
8 (203)
17 (432)
10.5 (267) 6.5 (165)
22 (559)
13 (330) 6.5 (165) 15.5 (394)
o
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
o
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE
12 (305)
8.5 (216)
22 (559)
13 (330)
8 (203)
17 (432)
8 (203)
4.5 (114) 17.5 (445) 8.5 (216) 6.5 (165) 15.5 (394)
inches)
(152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT de Classe "A", ou une
11.75 (298) 8.25 (210) 23.5 (597) 14.5 (368)
N/A
N/A
o
C Factory-built chimney.
o
C cheminée bâtit en usine.
VUE DU HAUT DE L'ALCÔVE
H*
G G
DISCOVERY-II-C
OUTSIDE APEX
PART NAME:
DRAWN BY:
SCALE:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
7033-353D
PART NAME
SERIAL RATING PLATE
BARCODE LABEL
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6
inches)
(152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six
(6 inches)
(152mm) de diamètre, le connecteur du conduit
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe
"A:, ou une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
G
H
CONDUIT DU MUR SIMPLE
48 (1220)
12 (305)
Modèle au dessus en appartement
Modèle au dessus en escalier
A
CONDUIT DU MUR DOUBLE
48 (1220)
9 (229)
Modèle au dessus en appartement
Modèle au dessus en escalier
CONDUIT DU MUR SIMPLE
48 (1220)
12 (305)
Modèle au dessus en appartement
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
CORNER INSTALLATION
48 (1220)
9 (229)
Modèle au dessus en appartement
INSTALLATION DU COIN
Modèle au dessus en escalier
E
inches
(1220mm) avec une hauteur
CONDUIT DU MUR DOUBLE
48 (1220)
*
Modèle au dessus en appartement
Modèle au dessus en escalier
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE L'ALCÔVE
ALCOVE TOP VIEW /
G
C
D
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission standards using crib
wood at
1.9
G/HR EPA Method 28 and 5G. This wood heater needs
periodic inspection and repair for proper operation. Consult the owner's
manual for further information. It is against federal regulations to operate
this wood heater in a manner inconsistent with the operating instructions
in the owner's manual.
(3) PLACE DEC: ± 0.005
ANGLE: ± 2°
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
MATERIAL:
PART NUMBER:
SHEET:
QTY
1
Serial
No.
Model
Name
Test Lab &
B
Report No.
C
D
F
E
F
A
B
Mfg. Date
7033-354C
FRACTION: ± 1/16
REV:
September 25, 2019

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents