Download Print this page
Vent-Axia HR100S Installation And Maintenance Instructions Manual

Vent-Axia HR100S Installation And Maintenance Instructions Manual

Heat recovery ventilation unit

Advertisement

Quick Links

HR100S
Heat Recovery Ventilation Unit
Surface mounting two speed heat recovery extract
and intake unit for bathrooms and toilets.
Installation and Maintenance Instructions
 
 
 
Stock Ref No:-
HR100S
141 10 010

Advertisement

loading

Summary of Contents for Vent-Axia HR100S

  • Page 1 HR100S   Heat Recovery Ventilation Unit   Surface mounting two speed heat recovery extract and intake unit for bathrooms and toilets. Installation and Maintenance Instructions   Stock Ref No:- HR100S 141 10 010...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY INFORMATION PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING INSTALLATION.   1. Do not install this product in areas where the following may be present or occur: • Excessive oil or a grease laden atmosphere. • Corrosive or flammable gases, liquids or vapours. •...
  • Page 3: Installation Guidance

    10. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 11.
  • Page 4: Product Description

    PRODUCT DESCRIPTION The HR100S is a surface mounting heat recovery ventilation unit for use in bathrooms and toilets. It is designed for mounting on an external wall having a thickness from 100 to 400mm. The units twin impeller and heat recovery arrangement simultaneously supplies and extracts air while transferring heat from the stale exhaust airflow to the fresh intake airflow.
  • Page 5 6. Withdraw the heat exchanger from the housing by grasping and gently but firmly pulling on its central vertical member. 7. Offer the housing to the inner mounting surface and, with the duct spigot located over the duct, mark the two fixing hole positions on the mounting surface. 8.
  • Page 6 1. Switch off the mains electrical supply. 2. Remove the cover from the unit after removing the two retaining screws in the side and slackening the two retaining screws in the bottom of the cover. 3. Remove the filter from inside the cover. 4.
  • Page 7                                                    ...
  • Page 8  ...
  • Page 9                                                      ...
  • Page 10                                                      ...
  • Page 11 PRODUCT FICHE  For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)  No 1254/2014)  Name:   Vent‐Axia   Model ID (Stock Ref.) :  HR100S ‐ 14110010  SEC Class  E  SEC Value ('Average')  ‐15.40  SEC Value ('Warm')  3.32  SEC Value ('Cold')  ‐48.86  Label Required? (Yes/No=Out of scope)  Yes  Declared as: RVU or NRVU/UVU or BVU  BVU   Speed Drive  Multi‐Speed  Type HRS (Recuperative, Regenerative, None)  Recuperative   Thermal Eff: [ (%), NA(if none)]  60.00  Max. Flow Rate (m3/h)  10.00  Max. Power Input (W): (@Max.Flow Rate)  35.00  LWA: Sound Power Level (dB)  47.52  Ref. Flow Rate (m3/s)  25.20  Ref. Pressure Diff. (Pa)  TBC  SPI [W/(m3/h)]  0.56  Control Factor & Control Typology: (CTRL/ Typology)     Control Factor; CTRL  1.00 ...
  • Page 12 United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:-...